Drilling Engineering LAMBDAs
Well control, circulating hydraulics, hole cleaning, directional surveys, pore pressure and fracture gradient, and casing design, as self-contained worksheets and the `PO.DE.*`, `PO.GM.*`, `PO.WI.*` and `PO.CO.Schematic.Depths` LAMBDAs they are built from.
82 lambdas
PO.DE.Hydrostatic
Hydrostatic pressure at the bottom of a column of mud. P = 0.052 × MW × TVD psi, with MW in ppg and TVD in ft. The depth is true vertical depth, not measured depth.
PO.DE.WellControl.KillMudWeight
Mud weight that balances the formation pressure after a kick. KMW = MW + SIDPP / (0.052 × TVD) ppg, with TVD the bit's true vertical depth. No trip margin is added; round up as the well-control policy requires.
PO.DE.WellControl.ICP
Drill pipe pressure to hold when the kill starts, in the wait-and-weight method. ICP = SIDPP + P_SCR, the shut-in drill pipe pressure plus the slow circulating rate pressure at the kill rate.
PO.DE.WellControl.FCP
Drill pipe pressure to hold once kill mud reaches the bit, in the wait-and-weight method. FCP = P_SCR × KMW / MW: the friction loss at the kill rate scales with the density of the mud in the string.
PO.DE.WellControl.MAASP
Surface casing pressure at which the shoe would break down, with the current mud in the hole. MAASP = (EMW_LOT − MW) × 0.052 × TVD_shoe psi, with EMW_LOT the leak-off test result as an equivalent mud weight.
PO.DE.WellControl.InfluxGradient
Pressure gradient of a kick, used to tell gas from oil or water. G_i = 0.052 × MW − (SICP − SIDPP) / H psi/ft, with H the vertical height of the influx in the annulus. Below about 0.25 psi/ft the influx is gas; above about 0.40 it is water.
PO.DE.PipeCapacity
Internal capacity of a pipe or casing string per foot of length, from its inside diameter. Capacity = ID² / 1029.4 bbl/ft. The constant converts square inches times feet to barrels.
PO.DE.AnnularCapacity
Volume per foot of the annulus between a hole (or casing ID) and the pipe inside it. Capacity = (Dh² − Dp²) / 1029.4 bbl/ft, with Dh the hole or casing inside diameter and Dp the pipe outside diameter.
PO.DE.Accumulator.UsableVolume
Hydraulic fluid one accumulator bottle delivers between its maximum and minimum operating pressures. V_usable = V × P_pre × (1/P_min − 1/P_max) gal, Boyle's law on the nitrogen precharge (isothermal).
PO.DE.Accumulator.PressureAfterDraw
Pressure left in an accumulator bottle after some of its fluid is used. P = V P_pre / (V P_pre / P_max + V_drawn) psi: the nitrogen volume at P_max grows by the fluid drawn.
PO.DE.BOP.ClosingVolume
The hydraulic fluid an accumulator has to deliver to operate a list of BOP functions once: each function's volume times how many there are, summed, times a design factor. Pass the volumes and the counts as two ranges of the same size, for example a stack table with one row per function. A design factor of 1 gives the bare volume to operate everything once.
PO.DE.BOP.Precharge
The nitrogen precharge of an accumulator bank that gives up a stated volume of fluid as its pressure falls from one value to another, by Boyle's law. One formula answers two questions. Measured: draw V_drawn gal from the bank with the charge pumps off, read the pressure before and after, and it returns the bank's average precharge. Design: put the fluid a stack needs as V_drawn, the fully charged pressure as P_start and the minimum operating pressure as P_final, and it returns the lowest precharge that still delivers that fluid above the minimum.
PO.DE.KickTol.Volume
The largest kick, in barrels at the bit, that a well can shut in and circulate out without breaking down the casing shoe. It uses the single-bubble method for a design kick intensity and influx gradient. The shoe allows an influx of height H = (MAASP − 0.052 × KI × TVD) / (0.052 × MW − G_influx). Two volumes follow from it: that height around the BHA at the bit, and that height around the drill pipe at the shoe, taken back to bottom-hole pressure by Boyle's law because the bubble expands on its way up. The kick tolerance is the smaller. Output 0 returns it, 1 the height H in ft, 2 the volume from the shoe case and 3 the volume at the bit.
PO.DE.KickTol.Intensity
The largest kick intensity the casing shoe can take with a given influx at the bit. It is how far the formation pressure can be above the mud weight, as an equivalent mud weight in ppg, before the shut-in casing pressure reaches MAASP. With no influx it is the kick tolerance factor, (shoe TVD / TVD) × (leak-off EMW − MW). Each barrel of influx displaces mud, so the shoe takes less.
PO.WI.Kill.Bullhead
The highest surface pressure allowed while bullheading, which pumps kill fluid down a string to push the well's fluids back into the formation. It must not fracture the formation: the limit is the fracture pressure at the weak point less the hydrostatic pressure of the column above it. As kill fluid replaces the initial column, the column gets heavier and the limit falls, in a straight line with the volume pumped for a string of one capacity. V_pumped of 0 returns the initial limit, and V_pumped of V_string or more returns the final one, with the string full of kill fluid.
PO.WI.Kill.FluidLoss
How fast a permeable zone takes kill fluid at an overbalance, by steady radial Darcy flow, and how much it takes over a period. The same formula gives the rate a zone accepts fluid when bullheading at a given pressure over the formation's. Output 0 returns the rate in bbl/hr and 1 the volume over Time_hr in bbl.
PO.WI.Barrier.Status
The status of one well barrier, the primary or the secondary, from the statuses of the well barrier elements (WBEs) that make it up. NORSOK D-010 defines a well barrier as an "envelope of one or several well barrier elements preventing fluids from flowing unintentionally from the formation into another formation or to surface". The envelope is closed only if every element is, so it is only as good as its worst element. Each element's status is a code: 0 for intact (tested and verified), 1 for degraded or not verified, 2 for failed. The envelope takes the highest code among its elements. Blank cells are ignored, so a table can list more element slots than a given well uses, and an envelope with no element at all is failed: there is nothing to stop the flow. A code above 2 counts as failed. Feed the two envelopes' statuses to `PO.WI.Barrier.Rating` for the well's integrity category.
PO.WI.Barrier.Rating
A well's integrity category from the status of its two well barriers. NORSOK D-010 requires two independent barriers, the primary and the secondary, during every well activity; how far the well is from losing both sets how urgently it needs attention. The categories are the four colours of the Norwegian Oil and Gas well-integrity classification: - 1, green: both barriers intact. - 2, yellow: one barrier degraded, the other intact. - 3, orange: one barrier failed and the other intact, or both degraded, so one more failure leaves a single weak barrier. - 4, red: one barrier failed and the other degraded or failed: one further failure, or none, opens a path to surface. Each status is a code, as `PO.WI.Barrier.Status` returns it: 0 intact, 1 degraded or not verified, 2 failed. The rating is symmetric: it does not matter which barrier is the weaker one.
PO.DE.ECD
Equivalent circulating density: the mud weight the formation sees while the mud is circulating. ECD = MW + ΔP_ann / (0.052 × TVD) ppg, where ΔP_ann is the annular frictional pressure loss above the point of interest.
PO.DE.Rheo.PowerLawIndex
Flow behavior index n of a power-law mud from the Fann viscometer. n = 3.32 log10(θ600 / θ300). It is 1 for a Newtonian fluid and falls as the mud shear-thins.
PO.DE.Rheo.PowerLawK
Consistency index K of a power-law mud, in equivalent centipoise, the unit the pressure-loss LAMBDAs take. K = 510 θ300 / 511ⁿ eq cp.
PO.DE.Rheo.HerschelBulkley
Shear stress of a yield power-law (Herschel-Bulkley) mud at a shear rate. τ = τy + K γ̇ⁿ. The stress comes out in the units of τy and K; with the viscometer convention both are lbf/100 ft².
PO.DE.Hyd.PipeReynolds
Reynolds number for a power-law mud flowing inside a pipe. v = Q / (2.448 ID²) ft/s and Re = 89100 MW v^(2−n) / K × (0.0416 ID / (3 + 1/n))ⁿ, with K in eq cp. Flow is laminar below 3470 − 1370n (API RP 13D).
PO.DE.Hyd.PipeLoss
Frictional pressure loss inside a pipe for a power-law mud. The Reynolds number is the one PO.DE.Hyd.PipeReynolds returns, computed in place so the LAMBDA stands alone. Below the API RP 13D limit 3470 − 1370n the laminar power-law equation applies; above it the Blasius friction factor f = 0.0791 / Re^0.25 does.
PO.DE.Hyd.AnnulusReynolds
Reynolds number for a power-law mud in an annulus, treated as a slot. v = Q / (2.448 (Dh² − Dp²)) ft/s and Re = 109000 MW v^(2−n) / K × (0.0208 (Dh − Dp) / (2 + 1/n))ⁿ, with K in eq cp.
PO.DE.Hyd.AnnulusLoss
Frictional pressure loss in an annulus for a power-law mud, with the annulus treated as a slot. The Reynolds number is the one PO.DE.Hyd.AnnulusReynolds returns, computed in place so the LAMBDA stands alone. Below 3470 − 1370n the laminar slot equation applies; above it the Blasius friction factor does. Feed the result to PO.DE.ECD.
PO.DE.PressureToBreakCirculation
Pump pressure needed to break the gels in a pipe after the mud has been static. P = τ_gel L / (300 ID) psi, with the gel strength in lbf/100 ft². Sum it over the string components; the annulus uses the same form with Dh − Dp in place of ID.
PO.DE.Bit.NozzleArea
Flow area of one bit nozzle from its size in 32nds of an inch. Sum the nozzles for the total flow area (TFA). A = π/4 (size/32)² in².
PO.DE.Bit.NozzlePressureLoss
Pressure drop across the bit nozzles. ΔP_bit = MW Q² / (10858 TFA²) psi. The constant 10858 = 12032 × 0.95² embeds a nozzle discharge coefficient of 0.95.
PO.DE.Bit.JetVelocity
Velocity of the mud leaving the bit nozzles. v_n = 0.3208 Q / TFA ft/s.
PO.DE.Bit.HydraulicHP
Hydraulic power spent across the bit nozzles. HHP = ΔP_bit Q / 1714 hp.
PO.DE.Bit.HSI
Bit hydraulic horsepower per square inch of hole area, the usual measure of bottom-hole cleaning. HSI = HHP / (π/4 × D_bit²) hp/in².
PO.DE.Bit.ImpactForce
Force of the nozzle jets on the bottom of the hole. F = 0.01823 × 0.95 × Q √(MW ΔP_bit) lbf, with the same 0.95 discharge coefficient as PO.DE.Bit.NozzlePressureLoss.
PO.DE.AnnularVelocity
Average upward velocity of the mud in an annulus, the first check on hole cleaning. AV = 24.5 Q / (Dh² − Dp²) ft/min, with Q in gpm and the diameters in inches.
PO.DE.Cuttings.Volume
Volume of solid rock cut per foot of hole drilled. V = Dh² / 1029.4 × (1 − φ) bbl/ft. Feed it to PO.DE.Cuttings.Concentration.
PO.DE.Cuttings.Concentration
Volume percent of cuttings in the returning mud, with no slip between cuttings and mud. C = 100 q_c / (Q/42 + q_c), with q_c = ROP × V_cuttings / 60 bbl/min. Values above about 5% call for a lower ROP or a higher flow rate.
PO.DE.HC.SlipVelocity
How fast a drilled cutting falls back through a power-law mud rising in the annulus, by Moore's correlation. The mud's apparent viscosity is taken at the shear rate of the annular flow, and the drag regime (laminar, intermediate or turbulent) is chosen from the particle Reynolds number. The result is in ft/min, the unit of `PO.DE.AnnularVelocity`, so the two subtract to the cuttings' net rise velocity and give the transport ratio (`PO.DE.HC.TransportRatio`).
PO.DE.HC.TransportRatio
The share of the mud's annular velocity that the cuttings keep: their net rise velocity over the annular velocity. A ratio of 1 carries every cutting out at the mud's speed; at 0 or below the cuttings hang or settle. FT = 1 − vs / va, dimensionless.
PO.DE.Solids.Fraction
Volume percent of solids in a mud of base fluid and one solids phase. Solids % = 100 (MW − MW_base) / (ρ_s − MW_base), all in ppg. A solids specific gravity converts to ppg as 8.34 × SG.
PO.DE.Mud.Dilution
Volume of lighter fluid to add to bring a mud system down to a target weight. V_add = V (MW_start − MW_target) / (MW_target − MW_dilute) bbl, a mass balance with no volume removed.
PO.DE.Mud.WeightUp
Weighting agent (barite, or hematite or calcium carbonate) needed to raise a mud system to a target weight, and the volume it adds to the system, with no mud removed. Returns four cells: the agent in lb, the same in 100-lb sacks, the volume added in bbl, and the final system volume in bbl.
PO.DE.Mud.Blend
Volumes of two muds of different weights to mix for a final volume at a target weight, for building a pill or a kill-weight batch from what is in the pits. Returns two cells, both bbl: the volume of mud A, then the volume of mud B.
PO.DE.Mud.OilWaterRatio
Oil-water ratio (OWR) of an oil-based or synthetic-based mud from the retort's oil and water volume percents, the figure a mud report quotes as, for example, 80/20. Returns three cells, all percent: the oil share of the liquid, the water share of the liquid, and the retort solids (100 less oil and water).
PO.DE.Hole.EffectiveDiameter
Average open-hole diameter from a measured annular volume, such as a carbide lag or a cement returns check. D = √(1029.4 (V_ann + V_steel) / L) in, where V_steel is the volume of the pipe in the open hole by its outside diameter.
PO.DE.Surge.Burkhardt
The effective annular mud velocity Burkhardt's steady-state surge and swab model assigns to a pipe moving at a given speed: the mud the pipe displaces, plus the mud that clings to it. The surge (running in) or swab (pulling out) pressure is the annular friction loss at this velocity. v = vp (A / (Dh² − Dp²) + Kc) ft/min, where A is Dp² for closed-end pipe (Mode 0) and Dp² − Di² for open-end pipe (Mode 1).
PO.DE.Dir.DoglegSeverity
Dogleg severity between two survey stations. The dogleg β = 2 asin √(sin²(ΔI/2) + sin I₁ sin I₂ sin²(ΔA/2)), the haversine form of the arccos expression, which stays exact when a course barely changes direction. DLS = β × 100 / ΔMD °/100 ft.
PO.DE.Dir.RatioFactor
Ratio factor of the minimum curvature method, which bends the balanced-tangential increments onto a circular arc. RF = (2/β) tan(β/2), with β the course dogleg in radians, and 1 for a straight course.
PO.DE.Dir.MinCurv.dTVD
True vertical depth gained over a survey course by minimum curvature. ΔTVD = ΔMD/2 (cos I₁ + cos I₂) RF, with RF from PO.DE.Dir.RatioFactor.
PO.DE.Dir.MinCurv.dNorth
Northing gained over a survey course by minimum curvature. ΔN = ΔMD/2 (sin I₁ cos A₁ + sin I₂ cos A₂) RF.
PO.DE.Dir.MinCurv.dEast
Easting gained over a survey course by minimum curvature. ΔE = ΔMD/2 (sin I₁ sin A₁ + sin I₂ sin A₂) RF.
PO.DE.Dir.VerticalSection
Horizontal displacement projected onto the plane of the vertical section. VS = N cos(VSA) + E sin(VSA).
PO.CO.Schematic.Depths
The true vertical depth of a measured depth on a directional survey: the depth bookkeeping a completion schematic needs to state every shoe, packer, valve and perforation in both MD and TVD. The survey is the stations' measured depth, inclination, azimuth and TVD, the last worked down the stations by minimum curvature (`PO.DE.Dir.MinCurv.dTVD` with `PO.DE.Dir.RatioFactor`). Between two stations the well is the minimum-curvature arc that joins them, so a depth there is not read off a straight line. The direction a fraction f of the way along the arc is the stations' directions weighted by sin((1 − f)β) and sin(fβ), over sin β, where β is the course's dogleg. The TVD gained is the minimum-curvature increment from the station above to that point over the part of the course it covers, f × ΔMD, whose dogleg is fβ. A depth exactly on a station returns that station's TVD. Above the first station the well is taken as vertical, and below the last it runs straight on at the last station's inclination. Survey down to TD to avoid the second. MD_ft may be one depth or a column of depths, which returns a column of TVDs.
PO.DE.Dir.ClosureDistance
Straight-line horizontal distance from the surface location to a station. Closure = √(N² + E²).
PO.DE.Dir.ClosureAzimuth
Direction of a station from the surface location, in degrees from north, 0 to 360. Excel's ATAN2(x, y) takes x first, so ATAN2(N, E) is the angle from north toward east. A station on the surface location returns 0.
PO.DE.Dir.CurveTangent
The curve that takes a well from its present inclination to a tangent (hold) inclination at a constant build or drop rate, in the vertical plane: how much hole it needs, and the TVD and horizontal departure it gains. Output 0 returns the curve length (MD), 1 the TVD gained and 2 the horizontal departure gained, all in ft.
PO.DE.Dir.ToolfaceSteer
Where a dogleg drilled at a given toolface takes the hole: the new inclination and azimuth after a dogleg set at a toolface angle measured from the high side of the hole, right (clockwise looking down the hole) positive. This is the closed form of the Ragland ("Ouija board") diagram a directional driller reads to orient a motor or whipstock. Output 0 returns the new inclination, 1 the new azimuth (0 to 360°) and 2 the azimuth change (−180 to 180°, right positive), all in degrees.
PO.GM.Density.Gardner
Bulk density from P-wave velocity by Gardner's power law, the usual stand-in for a density log over a section logged only with sonic. Fill a density column with it, then pass the column to `PO.GM.Stress.Overburden`. Returns the bulk density in g/cc.
PO.GM.Stress.Overburden
Overburden (vertical) stress at a depth, by integrating a bulk-density log down from its first depth, the Sv every pore-pressure and fracture-gradient method starts from. Returns three cells: Sv in psi, the overburden gradient Sv/Z in psi/ft, and the same gradient as an equivalent mud weight in ppg.
PO.DE.PP.Eaton
Pore pressure in shale by Eaton's method, from how far a sonic or resistivity log departs from its normal-compaction trend at the same depth. Undercompacted, overpressured shale is slower (higher transit time) and more conductive (lower resistivity) than the trend. Returns the pore pressure in the unit Sv and Pn are given in: psi, psi/ft or ppg.
PO.DE.FG.Eaton
Fracture pressure or gradient by Eaton's method: the pore pressure plus the share of the effective overburden that Poisson's ratio transmits to the horizontal. It is the upper bound of the mud-weight window. Returns the fracture pressure in the unit Sv and Pp are given in: psi, psi/ft or ppg.
PO.DE.FG.MatthewsKelly
Fracture pressure or gradient by Matthews and Kelly: the pore pressure plus a matrix-stress coefficient times the effective overburden (the matrix stress). The coefficient comes from their empirical chart, or from leak-off tests in the area. Returns the fracture pressure in the unit Sv and Pp are given in: psi, psi/ft or ppg.
PO.GM.Stress.MinHorizontal
The minimum and maximum horizontal stresses by the uniaxial-strain (poroelastic) model, with tectonic strain terms: the stresses of a 1D mechanical earth model, the fracture closure stress and the frac-barrier contrast between layers. Returns two cells, in the unit of Sv, Pp and E (psi): Shmin, then SHmax.
PO.GM.Elastic.Dynamic
Dynamic Young's modulus, Poisson's ratio, shear modulus and bulk modulus from the compressional and shear velocities of a dipole sonic log and the bulk density, the first step of a log-based mechanical earth model. Returns four cells: E in psi, Poisson's ratio, G in psi and K in psi.
PO.GM.Strength.UCS
Unconfined compressive strength (UCS) of a rock from its compressional sonic transit time, by a named empirical correlation: McNally's for sandstone or Horsrud's for shale. UCS is the strength input of wellbore-stability and sanding checks. Returns two cells: UCS in MPa (the unit the correlations are fitted in), then in psi.
PO.DE.Casing.Burst.API5C3
Pipe-body internal yield pressure (the burst rating) of casing or tubing, as API TR 5C3 and ISO 10400 tabulate it for API 5CT pipe. P = 0.875 × 2 Yp t / D psi: Barlow's equation at the API 5CT minimum wall of 87.5% of nominal.
PO.DE.Casing.Collapse.API5C3
Minimum collapse resistance of casing or tubing under external pressure, by the four API collapse equations. The regime is chosen from the D/t ratio and the grade, and axial tension can reduce the rating through the API axial-stress equivalent grade. Output 0 returns the collapse pressure in psi, 1 adds the regime (1 yield, 2 plastic, 3 transition, 4 elastic) as a second cell, and 2 returns the grade's three regime D/t limits.
PO.DE.Casing.Axial.Yield
Pipe-body yield strength of casing or tubing: the axial tension at which the body reaches the minimum yield strength of its grade. Fy = (π/4)(D² − d²) Yp lbf, with d = D − 2t.
PO.DE.Casing.LoadCase
Net pressure load on a casing string at one depth for the standard burst and collapse load cases, with the external backup. Evaluated down a depth column, it gives the load line that the burst or collapse rating is compared against. Cases 1 and 2 (burst) return internal minus external pressure in psi, cases 3 and 4 (collapse) external minus internal.
PO.DE.Casing.DesignFactor
Design factor of a casing string against one load, and whether it meets the minimum design factor set for that load. DF = Rating / Load. Returns two cells: DF, then 1 when DF ≥ DF_min and 0 otherwise.
PO.DE.Casing.VonMises
Triaxial equivalent stress in a casing or tubing wall at radius r, for a triaxial design check against the minimum yield strength. The triaxial design factor is Yp divided by this stress. σvm = √{[(σa − σr)² + (σr − σθ)² + (σθ − σa)²] / 2} psi, with σr and σθ from Lamé's thick-wall equations.
PO.DE.TD.Buoyancy
Buoyancy factor of a pipe string with one fluid inside and another outside, and its buoyed weight per foot, for hookload, torque-and-drag and buckling work. Returns two cells: BF = 1 − (ρo D² − ρi d²) / (ρs (D² − d²)), then the buoyed weight W × BF in lb/ft.
PO.DE.TD.Stretch
Elastic stretch of a pipe string hanging free, from a load at its lower end plus its own buoyed weight (Hooke's law). Use it for hookload stretch, free-point estimates from an overpull, and space-out. ΔL = 12 L (F + W L / 2) / (E As) in., with As = π/4 (D² − d²).
PO.DE.TD.Buckling.Sinusoidal
The axial compression at which a pipe lying in a hole starts to buckle sinusoidally: Dawson and Paslay in an inclined hole, Lubinski in a vertical one. Mode 0 returns Fcr = 2 √(E I w sin θ / r) lbf; Mode 1 returns Fcr = 1.94 (E I w²)^(1/3) lbf.
PO.DE.TD.Buckling.Helical
The axial compression above which a pipe in a hole buckles into a helix, the load that drives lock-up in torque and drag and the critical load `PO.CO.Tubing.Buckling` takes. Mode 0 returns Fhel = √2 × 2 √(E I w sin θ / r) lbf, √2 times the Dawson-Paslay load; Mode 1 returns Fhel = 5.55 (E I w²)^(1/3) lbf for a vertical hole.
PO.DE.Cement.Volume
Slurry volume of one cement stage (a lead or a tail): the open-hole annulus with an excess, the overlap inside the previous casing, and the shoe track. Call it once per slurry; a lead usually has no shoe track, a tail no overlap. Returns four cells, all bbl: the total, then the open-hole, overlap and shoe-track parts.
PO.DE.Cement.Displacement
The volume of displacement fluid that takes the top plug from surface to the float collar, and the pump strokes to bump it. Returns two cells: the volume, ID²/1029.4 × FC + Extra bbl, then the strokes, the volume over the pump output.
PO.WI.PA.BalancedPlug
Placement of a balanced cement plug through an open-ended string: the spacer to pump behind the cement so the columns inside and outside the pipe balance, the plug height with the pipe in, its height after the pipe is pulled, and the displacement. Returns four cells: spacer behind (bbl), plug height with the pipe in (ft), plug height after pulling out (ft), displacement (bbl).
PO.CO.Tubing.Piston
Lubinski's piston effect: the force a pressure change at the packer puts on the end of a tubing string that seals in a packer bore, and the length change it causes if the tubing is free to move. Returns two cells: F1 = (Ap − Ai) ΔPi − (Ap − Ao) ΔPo lbf, then ΔL1 = −12 L F1 / (E As) in.
PO.CO.Tubing.Ballooning
Lubinski's ballooning effect: pressure inside the tubing swells it and shortens it (ballooning), pressure outside squeezes it and lengthens it (reverse ballooning). Returns the equivalent force and the free-tubing length change, from the changes of the average pressures. Returns two cells: F2 = 2ν (ΔPia Ai − ΔPoa Ao) lbf, then ΔL2 = −12 L F2 / (E As) in.
PO.CO.Tubing.Thermal
Lubinski's temperature effect: the length change of free tubing when its average temperature changes, and the force a packer takes when the tubing cannot move. Cooling (injection, a stimulation) shortens the tubing; heating (production) lengthens it. Returns two cells: F3 = −E β As ΔT lbf, then ΔL3 = 12 L β ΔT in.
PO.CO.Tubing.Buckling
Lubinski's buckling effect: tubing compressed above its packer coils into a helix against the casing and shortens. Returns the length change and the buckled length above the packer, from the fictitious force at the packer and a critical helical load. Returns two cells: ΔL4 = −r² (Ff² − F²low) / (8 E I w) in., then the buckled length (Ff − Flow) / W ft, both 0 when Ff ≤ Fcr.
PO.DE.AFE.TimeDepth
One hole section of a time-depth (days versus depth) curve and its cost: drilling time from the ROP, round trips to the section's base, and flat time, priced at the spread rate plus the section's fixed costs, and added to the totals of the sections above. Returns four cells: section days, cumulative days, section cost and cumulative cost.