PO.WI.Kill.FluidLoss


Description

How fast a permeable zone takes kill fluid at an overbalance, by steady radial Darcy flow, and how much it takes over a period. The same formula gives the rate a zone accepts fluid when bullheading at a given pressure over the formation's. Output 0 returns the rate in bbl/hr and 1 the volume over Time_hr in bbl.

Formula

=LAMBDA(k_md, h_ft, dP_psi, mu_cp, re_ft, Dh_in, Time_hr, Output, LET( rate, 0.00708 * k_md * h_ft * dP_psi / (mu_cp * LN(re_ft / (Dh_in / 24))) / 24, IF(Output = 1, rate * Time_hr, rate)))

Parameters

Parameter Unit Description
k_md md Permeability of the zone
h_ft ft Height of the zone open to the well
dP_psi psi Overbalance: wellbore pressure less formation pressure at the zone
mu_cp cp Viscosity of the fluid entering the zone (filtrate, brine or whole mud)
re_ft ft Radius the fluid has invaded to, or the drainage radius
Dh_in in Hole diameter at the zone
Time_hr hr Time the zone is exposed (used by Output 1)
Output dimensionless 0 rate, bbl/hr; 1 volume over Time_hr, bbl

Examples

Invocation Expected
=PO.WI.Kill.FluidLoss(200, 20, 624, 0.3, 3.694528, 12, 1, 0) 1200
=PO.WI.Kill.FluidLoss(200, 20, 624, 0.3, 3.694528, 12, 1, 1) 1227.2
=PO.WI.Kill.FluidLoss(50, 20, 100, 1, 500, 8.5, 24, 1) 97.6202

Need a custom LAMBDA? Suggest a New Lambda