Discharge Temperature and Power LAMBDAs
The adiabatic discharge temperature of a stage, and adiabatic or polytropic head and gas power.
2 lambdas
PO.SF.Comp.Tdisch(t, ratio, k, eff)
Returns the discharge temperature of one compression stage from its suction temperature, its pressure ratio, the gas's ratio of specific heats and the isentropic efficiency. With an efficiency of 1 it is the ideal isentropic temperature T1·r^((k−1)/k); below 1 the extra work also goes into the gas, so the rise is the isentropic rise over the efficiency. The discharge temperature is what limits a stage's ratio, so a staging sheet checks it per stage.
PO.SF.Comp.Power(mode, qg, ps, pd, t, sg, z, k, eff, stages, output)
Returns the head per stage, the gas power per stage or the total gas power to compress a gas rate from a suction to a discharge pressure in equal-ratio stages, with the gas cooled back to the suction temperature between stages. The mode is required: "Adiabatic" takes the isentropic head and the isentropic efficiency, the usual basis for reciprocating machines; "Polytropic" takes the polytropic head and the polytropic efficiency, the usual basis for centrifugal ones. The result is gas power, the power delivered to the gas: brake power adds the mechanical losses (bearings, seals, gear), which the caller adds.