ESP Pump Curves LAMBDAs
Catalog-curve head, efficiency and power versus rate, best efficiency point and operating range, and the affinity laws that move a curve with speed.
10 lambdas
PO.ESP.Curve.Head.SI(Q, curve_Q, curve_Head)
Interpolates head from pump performance curve (SI units), [m/stage].
PO.ESP.Curve.Efficiency.SI(Q, curve_Q, curve_Eff)
Interpolates efficiency from pump performance curve (SI units), [fraction].
PO.ESP.Curve.Power.SI(Q, curve_Q, curve_HP)
Interpolates power per stage from pump curve (SI units), [kW].
PO.ESP.Curve.BEP.SI(curve_Q, curve_Eff)
Returns Best Efficiency Point flow rate from pump curve (SI units), [m3/d].
PO.ESP.Curve.BEP.Eff.SI(curve_Q, curve_Eff)
Returns maximum efficiency value from pump curve (SI units), [fraction].
PO.ESP.Affinity.Rate(q, f, f_base)
Pump rate at a new speed from the rate at the base frequency, by the affinity laws. q(f) = q × f / f_base. Any rate unit works; the result is in the same unit.
PO.ESP.Affinity.Head(h, f, f_base)
Pump head at a new speed from the head at the base frequency, by the affinity laws. h(f) = h × (f / f_base)². Any head unit works; the result is in the same unit.
PO.ESP.Affinity.Power(p, f, f_base)
Pump brake power at a new speed from the power at the base frequency, by the affinity laws. p(f) = p × (f / f_base)³. Any power unit works; the result is in the same unit.
PO.ESP.Curve.HeadAtSpeed(q, f, f_base, curve_q, curve_head)
Head per stage at a rate and a frequency, from a pump curve published at the base frequency. The rate is moved back to the base frequency, q × f_base / f, the curve is read there with PO.ESP.Curve.Head, and the head is moved forward with the affinity law (f / f_base)². Past the curve's run-out the result is 0, which keeps a tabulated operating-point solve monotone.
PO.ESP.Curve.PowerAtSpeed(q, f, f_base, curve_q, curve_hp)
Brake power per stage on water at a rate and a frequency, from a pump curve published at the base frequency. The rate is moved back to the base frequency, the curve is read with PO.ESP.Curve.Power, and the power is moved forward with (f / f_base)³. Multiply by the fluid specific gravity for another fluid. Past run-out the result is #N/A.