Rod Pump Performance LAMBDAs
Volumetric displacement, stroke length and pump intake conditions.
9 lambdas
PO.RP.Pump.Displacement.SI(Ap, Sp, N)
Calculates theoretical pump displacement (SI units), [m3/d].
PO.RP.Pump.Displacement.FromDiameter.SI(d, Sp, N)
Calculates theoretical pump displacement from plunger diameter (SI units), [m3/d].
PO.RP.Pump.Disp.Eff.SI(PD, F)
Calculates effective pump displacement accounting for fillage (SI units), [m3/d].
PO.RP.Pump.Fillage.SI(Qa, PD)
Calculates pump fillage from actual and theoretical production (SI units), [fraction].
PO.RP.Pump.VolEff.SI(Qa, PD)
Calculates volumetric efficiency of the pump system (SI units), [fraction].
PO.RP.Pump.Stroke.Eff.SI(S, dLr, dLt)
Calculates effective plunger stroke from surface stroke and stretch (SI units), [cm].
PO.RP.Pump.Psub.SI(h, G)
Calculates submergence pressure from fluid column height (SI units), [kPa].
PO.RP.Pump.PIP.SI(Pwf, Psub)
Calculates pump intake pressure (PIP) (SI units), [kPa].
PO.RP.Fluidlevel.Echo(t_echo, v_acoustic, joints, joint_len, pump_depth, output)
The depth of the liquid level in the casing annulus from an acoustic (echometer) shot, and the submergence of the pump below it. A pressure pulse fired at the casinghead travels down the gas column, reflects off the liquid and returns: the level is half the round trip, v·t/2, at the acoustic velocity of the annulus gas. When the tubing collars' echoes are counted down to the liquid echo, the level is the joints counted times the average joint length instead, and the velocity the level implies (2·level/t) checks the gas. A pump with little fluid over it is pumped off; one with much is under-pumped.