PO.RP.Fluidlevel.Echo
Description
The depth of the liquid level in the casing annulus from an acoustic (echometer) shot, and the submergence of the pump below it. A pressure pulse fired at the casinghead travels down the gas column, reflects off the liquid and returns: the level is half the round trip, v·t/2, at the acoustic velocity of the annulus gas. When the tubing collars' echoes are counted down to the liquid echo, the level is the joints counted times the average joint length instead, and the velocity the level implies (2·level/t) checks the gas. A pump with little fluid over it is pumped off; one with much is under-pumped.
Formula
=LAMBDA(t_echo, v_acoustic, joints, joint_len, pump_depth, output, IF(OR(t_echo<=0, pump_depth<=0, joints<0, AND(joints>0, joint_len<=0), AND(joints=0, v_acoustic<=0)), NA(), LET(
level, IF(joints>0, joints*joint_len, v_acoustic*t_echo/2), IF(output="Level", level, IF(output="Submergence", pump_depth-level, IF(output="Velocity", 2*level/t_echo, NA()))))))Parameters
| Parameter | Unit | Description |
|---|---|---|
t_echo |
s | Round-trip time from the shot to the liquid-level echo |
v_acoustic |
ft/s | Acoustic velocity of the annulus gas; not used when joints > 0 |
joints |
count | Tubing collars counted from surface to the liquid echo; 0 to use the velocity |
joint_len |
ft | Average tubing joint length, from the tally; used when joints > 0 |
pump_depth |
ft | Pump intake depth |
output |
text | "Level" (depth of the liquid level from surface, ft), "Submergence" (pump depth less the level, ft) or "Velocity" (the acoustic velocity the level implies, ft/s) |
Examples
| Invocation | Expected |
|---|---|
=PO.RP.Fluidlevel.Echo(7.2, 1250, 0, 31.5, 5000, "Level") |
4500 |
=PO.RP.Fluidlevel.Echo(7.2, 1250, 0, 31.5, 5000, "Submergence") |
500 |
=PO.RP.Fluidlevel.Echo(7.2, 1250, 143, 31.5, 5000, "Level") |
4504.5 |
=PO.RP.Fluidlevel.Echo(7.2, 1250, 143, 31.5, 5000, "Velocity") |
1251.25 |
=PO.RP.Fluidlevel.Echo(4, 1100, 0, 31.5, 2000, "Submergence") |
-200 |
=IF(ISNA(PO.RP.Fluidlevel.Echo(0, 1250, 0, 31.5, 5000, "Level")), 1, 0) |
1 |