PO.DE.ECD(MW_ppg, P_ann_psi, TVD_ft)

Equivalent circulating density: the mud weight the formation sees while the mud is circulating. ECD = MW + ΔP_ann / (0.052 × TVD) ppg, where ΔP_ann is the annular frictional pressure loss above the point of interest.

PO.DE.Rheo.PowerLawIndex(Theta600, Theta300)

Flow behavior index n of a power-law mud from the Fann viscometer. n = 3.32 log10(θ600 / θ300). It is 1 for a Newtonian fluid and falls as the mud shear-thins.

PO.DE.Rheo.PowerLawK(Theta300, FlowIdx)

Consistency index K of a power-law mud, in equivalent centipoise, the unit the pressure-loss LAMBDAs take. K = 510 θ300 / 511ⁿ eq cp.

PO.DE.Rheo.HerschelBulkley(Tau_y, K, GammaDot, n)

Shear stress of a yield power-law (Herschel-Bulkley) mud at a shear rate. τ = τy + K γ̇ⁿ. The stress comes out in the units of τy and K; with the viscometer convention both are lbf/100 ft².

PO.DE.Hyd.PipeReynolds(Q_gpm, ID_in, MW_ppg, n, K_cp)

Reynolds number for a power-law mud flowing inside a pipe. v = Q / (2.448 ID²) ft/s and Re = 89100 MW v^(2−n) / K × (0.0416 ID / (3 + 1/n))ⁿ, with K in eq cp. Flow is laminar below 3470 − 1370n (API RP 13D).

PO.DE.Hyd.PipeLoss(Q_gpm, ID_in, L_ft, MW_ppg, n, K_cp)

Frictional pressure loss inside a pipe for a power-law mud. The Reynolds number is the one PO.DE.Hyd.PipeReynolds returns, computed in place so the LAMBDA stands alone. Below the API RP 13D limit 3470 − 1370n the laminar power-law equation applies; above it the Blasius friction factor f = 0.0791 / Re^0.25 does.

PO.DE.Hyd.AnnulusReynolds(Q_gpm, Dh_in, Dp_in, MW_ppg, n, K_cp)

Reynolds number for a power-law mud in an annulus, treated as a slot. v = Q / (2.448 (Dh² − Dp²)) ft/s and Re = 109000 MW v^(2−n) / K × (0.0208 (Dh − Dp) / (2 + 1/n))ⁿ, with K in eq cp.

PO.DE.Hyd.AnnulusLoss(Q_gpm, Dh_in, Dp_in, L_ft, MW_ppg, n, K_cp)

Frictional pressure loss in an annulus for a power-law mud, with the annulus treated as a slot. The Reynolds number is the one PO.DE.Hyd.AnnulusReynolds returns, computed in place so the LAMBDA stands alone. Below 3470 − 1370n the laminar slot equation applies; above it the Blasius friction factor does. Feed the result to PO.DE.ECD.

PO.DE.PressureToBreakCirculation(GelStrength, L_ft, ID_in)

Pump pressure needed to break the gels in a pipe after the mud has been static. P = τ_gel L / (300 ID) psi, with the gel strength in lbf/100 ft². Sum it over the string components; the annulus uses the same form with Dh − Dp in place of ID.

PO.DE.Bit.NozzleArea(Size_32nds)

Flow area of one bit nozzle from its size in 32nds of an inch. Sum the nozzles for the total flow area (TFA). A = π/4 (size/32)² in².

PO.DE.Bit.NozzlePressureLoss(MW_ppg, Q_gpm, A_nozzle_in2)

Pressure drop across the bit nozzles. ΔP_bit = MW Q² / (10858 TFA²) psi. The constant 10858 = 12032 × 0.95² embeds a nozzle discharge coefficient of 0.95.

PO.DE.Bit.JetVelocity(Q_gpm, TFA_in2)

Velocity of the mud leaving the bit nozzles. v_n = 0.3208 Q / TFA ft/s.

PO.DE.Bit.HydraulicHP(dP_bit_psi, Q_gpm)

Hydraulic power spent across the bit nozzles. HHP = ΔP_bit Q / 1714 hp.

PO.DE.Bit.HSI(HHP_bit, Bit_in)

Bit hydraulic horsepower per square inch of hole area, the usual measure of bottom-hole cleaning. HSI = HHP / (π/4 × D_bit²) hp/in².

PO.DE.Bit.ImpactForce(MW_ppg, Q_gpm, dP_bit_psi)

Force of the nozzle jets on the bottom of the hole. F = 0.01823 × 0.95 × Q √(MW ΔP_bit) lbf, with the same 0.95 discharge coefficient as PO.DE.Bit.NozzlePressureLoss.

PO.DE.AnnularVelocity(Q_gpm, Dh_in, Dp_in)

Average upward velocity of the mud in an annulus, the first check on hole cleaning. AV = 24.5 Q / (Dh² − Dp²) ft/min, with Q in gpm and the diameters in inches.

PO.DE.Cuttings.Volume(Dh_in, Porosity)

Volume of solid rock cut per foot of hole drilled. V = Dh² / 1029.4 × (1 − φ) bbl/ft. Feed it to PO.DE.Cuttings.Concentration.

PO.DE.Cuttings.Concentration(ROP_fthr, V_cuttings_bblft, Q_gpm)

Volume percent of cuttings in the returning mud, with no slip between cuttings and mud. C = 100 q_c / (Q/42 + q_c), with q_c = ROP × V_cuttings / 60 bbl/min. Values above about 5% call for a lower ROP or a higher flow rate.

PO.DE.HC.SlipVelocity(Dc_in, RhoC_ppg, MW_ppg, n, K_eqcp, Dh_in, Dp_in, Va_ftmin)

How fast a drilled cutting falls back through a power-law mud rising in the annulus, by Moore's correlation. The mud's apparent viscosity is taken at the shear rate of the annular flow, and the drag regime (laminar, intermediate or turbulent) is chosen from the particle Reynolds number. The result is in ft/min, the unit of `PO.DE.AnnularVelocity`, so the two subtract to the cuttings' net rise velocity and give the transport ratio (`PO.DE.HC.TransportRatio`).

PO.DE.HC.TransportRatio(Vslip_ftmin, Va_ftmin)

The share of the mud's annular velocity that the cuttings keep: their net rise velocity over the annular velocity. A ratio of 1 carries every cutting out at the mud's speed; at 0 or below the cuttings hang or settle. FT = 1 − vs / va, dimensionless.

PO.DE.Solids.Fraction(MW_ppg, MW_base_ppg, Rho_solids_ppg)

Volume percent of solids in a mud of base fluid and one solids phase. Solids % = 100 (MW − MW_base) / (ρ_s − MW_base), all in ppg. A solids specific gravity converts to ppg as 8.34 × SG.

PO.DE.Mud.Dilution(V_start_bbl, MW_start_ppg, MW_target_ppg, MW_dilute_ppg)

Volume of lighter fluid to add to bring a mud system down to a target weight. V_add = V (MW_start − MW_target) / (MW_target − MW_dilute) bbl, a mass balance with no volume removed.

PO.DE.Mud.WeightUp(V_bbl, MW_start_ppg, MW_target_ppg, Rho_agent_ppg)

Weighting agent (barite, or hematite or calcium carbonate) needed to raise a mud system to a target weight, and the volume it adds to the system, with no mud removed. Returns four cells: the agent in lb, the same in 100-lb sacks, the volume added in bbl, and the final system volume in bbl.

PO.DE.Mud.Blend(V_final_bbl, MW_a_ppg, MW_b_ppg, MW_target_ppg)

Volumes of two muds of different weights to mix for a final volume at a target weight, for building a pill or a kill-weight batch from what is in the pits. Returns two cells, both bbl: the volume of mud A, then the volume of mud B.

PO.DE.Mud.OilWaterRatio(Oil_pct, Water_pct)

Oil-water ratio (OWR) of an oil-based or synthetic-based mud from the retort's oil and water volume percents, the figure a mud report quotes as, for example, 80/20. Returns three cells, all percent: the oil share of the liquid, the water share of the liquid, and the retort solids (100 less oil and water).

PO.DE.Hole.EffectiveDiameter(V_annulus_bbl, V_steel_bbl, L_ft)

Average open-hole diameter from a measured annular volume, such as a carbide lag or a cement returns check. D = √(1029.4 (V_ann + V_steel) / L) in, where V_steel is the volume of the pipe in the open hole by its outside diameter.

PO.DE.Surge.Burkhardt(Vp_ftmin, Dh_in, Dp_in, Di_in, Kc, Mode)

The effective annular mud velocity Burkhardt's steady-state surge and swab model assigns to a pipe moving at a given speed: the mud the pipe displaces, plus the mud that clings to it. The surge (running in) or swab (pulling out) pressure is the annular friction loss at this velocity. v = vp (A / (Dh² − Dp²) + Kc) ft/min, where A is Dp² for closed-end pipe (Mode 0) and Dp² − Di² for open-end pipe (Mode 1).

Need a custom LAMBDA? Request a Lambda