Gas Properties LAMBDAs
Z factor, pseudo-critical properties, gas density, viscosity and compressibility, the real-gas pseudo-pressure m(p), pure CO2 density, Z and viscosity, and the H2S partial pressure and radius of exposure of a sour gas.
15 lambdas
PO.HSE.Sour.PartialPressure(y_h2s, p)
The partial pressure of hydrogen sulfide in a gas, the mole fraction of H2S times the total absolute pressure: pH2S = y·P. It is the number NACE MR0175 / ISO 15156 classifies sour service by (0.05 psia, 0.3 kPa, is the sour limit) and the abscissa of its SSC severity figure (`PO.FA.Corrosion.H2S.Region`). The result is in the unit the pressure is given in: psia in, psia out.
PO.HSE.Sour.ROE(y_h2s, q, ppm)
The radius of exposure around a possible release of sour gas: the distance from the point of escape within which the H2S concentration may reach 100 ppm or 500 ppm, by the Pasquill-Gifford equations of Texas Railroad Commission Statewide Rule 36 (16 TAC §3.36(c)(2)). The radius is the rule's trigger for warning signs, protective equipment and a contingency plan: a 100 ppm radius over 50 ft that takes in a public area, a 500 ppm radius over 50 ft that takes in a public road, or a 100 ppm radius of 3,000 ft or more.
PO.PVT.Bg.ByDefinition.SI(P, T_K, Z)
Calculates gas formation volume factor by definition in SI units.
PO.PVT.Ug.ByLGE.SI(Z, SG_gas, P, T_K)
Calculates gas viscosity using Lee, Gonzalez and Eakin (1966) correlation (SI units), [mPa.s].
PO.PVT.Cg.ByDefinition.SI(P, T_K, SG_gas)
Calculates isothermal gas compressibility by definition (SI units), [1/kPa].
PO.PVT.Rho.Gas.ByDefinition.SI(P, T_K, SG_gas, Z)
Calculates gas density by definition (SI units), [kg/m3].
PO.PVT.PseudoP(p, t_r, sg_g, p_base, steps)
Returns the real-gas pseudo-pressure m(p) = 2∫ p/(μg·Z) dp of a natural gas, from a base pressure up to p, in psi²/cp. The pseudo-pressure takes the pressure dependence of the gas viscosity and Z-factor into the flow equation, so a gas well's deliverability and a gas well test can be written in m(p) at any pressure, where the pressure-squared form holds only while μg·Z stays constant (below about 2,000 psia). The difference m(Pr) − m(Pwf) is what a gas well's drawdown is measured in. Z comes from `PO.PVT.Z.ByDAK` and μg from `PO.PVT.Ug.ByLGE`, both at Sutton's pseudo-critical pressure and temperature for the gas gravity, at every step of the integral.
PO.PVT.Tpc.BySutton.SI(SG_gas)
Calculates pseudocritical temperature using Sutton (1985) correlation (SI units), [degK].
PO.PVT.Tpc.ByStanding.SI(SG_gas)
Calculates pseudocritical temperature using Standing (1977) correlation (SI units), [degK].
PO.PVT.Tpc.BySutton.Sour.SI(SG_gas, y_H2S, y_CO2)
Calculates pseudocritical temperature for sour gas using Sutton (1985) with Wichert-Aziz correction (SI units), [degK].
PO.PVT.Tpc.ByStanding.Sour.SI(SG_gas, y_H2S, y_CO2)
Calculates pseudocritical temperature for sour gas using Standing (1977) with Wichert-Aziz correction (SI units), [degK].
PO.PVT.Ppc.BySutton.SI(SG_gas)
Calculates pseudocritical pressure using Sutton (1985) correlation (SI units), [kPa].
PO.PVT.Ppc.ByStanding.SI(SG_gas)
Calculates pseudocritical pressure using Standing (1977) correlation (SI units), [kPa].
PO.PVT.Ppc.BySutton.Sour.SI(SG_gas, y_H2S, y_CO2)
Calculates pseudocritical pressure for sour gas using Sutton (1985) with Wichert-Aziz correction (SI units), [kPa].
PO.PVT.Ppc.ByStanding.Sour.SI(SG_gas, y_H2S, y_CO2)
Calculates pseudocritical pressure for sour gas using Standing (1977) with Wichert-Aziz correction (SI units), [kPa].