Polished Rod Loads LAMBDAs
Fluid load, peak and minimum polished rod load and the load range.
6 lambdas
PO.RP.Load.FluidLoad.SI(Ap, H, G)
Calculates fluid load on plunger (SI units), [N].
PO.RP.Load.PPRL.SI(Wrf, F1_over_Skr, Skr)
Calculates Peak Polished Rod Load using API RP 11L method, PPRL = Wrf + (F1/Skr)*Skr (SI units), [N].
PO.RP.Load.MPRL.SI(Wrf, F2_over_Skr, Skr)
Calculates Minimum Polished Rod Load using API RP 11L method, MPRL = Wrf − (F2/Skr)*Skr (SI units), [N].
PO.RP.Load.PPRL.Simple.SI(Wrf, Fo)
Calculates simplified PPRL (static, no dynamic effects) (SI units), [N].
PO.RP.Load.MPRL.Simple.SI(Wrf)
Calculates simplified MPRL (static, no dynamic effects) (SI units), [N].
PO.RP.Load.Range.SI(PPRL, MPRL)
Calculates polished rod load range (PPRL - MPRL) (SI units), [N].