Transient Well Pressure LAMBDAs
Wellbore pressure response during transient flow, the Horner buildup quantities (time ratio, permeability and skin from the semilog slope, p*), the drawdown and multi-rate straight-line fits, and test design: radius of investigation, duration and gauge resolution.
11 lambdas
PO.PTA.Pw.VW.SI(time, prod_data, B, Ul, C, Rw, S, Ct, porosity, h, K)
Calculates wellbore pressure drop for vertical well in infinite homogeneous reservoir (SI units), [kPa].
PO.PTA.Pw.VW.LinSealF.SI(time, prod_data, B, Ul, C, Rw, S, Ct, porosity, h, K, L)
Calculates wellbore pressure drop for vertical well in infinite homogeneous reservoir with linear sealing fault boundary (SI units), [kPa].
PO.PTA.Pw.VW.LinConP.SI(time, prod_data, B, Ul, C, Rw, S, Ct, porosity, h, K, L)
Calculates wellbore pressure drop for vertical well in infinite homogeneous reservoir with linear constant pressure boundary (SI units), [kPa].
PO.PTA.Pw.VW.PerpSealF.SI(time, prod_data, B, Ul, C, Rw, S, Ct, porosity, h, K, L1, L2)
Calculates wellbore pressure drop for vertical well in infinite homogeneous reservoir with perpendicular sealing faults boundary (SI units), [kPa].
PO.PTA.Pw.VW.PerpConP.SI(time, prod_data, B, Ul, C, Rw, S, Ct, porosity, h, K, L1, L2)
Calculates wellbore pressure drop for vertical well in infinite homogeneous reservoir with perpendicular constant pressures boundary (SI units), [kPa].
PO.PTA.Pw.VW.PerpMix.SI(time, prod_data, B, Ul, C, Rw, S, Ct, porosity, h, K, L1, L2)
Calculates wellbore pressure drop for vertical well in infinite homogeneous reservoir with perpendicular mixed boundaries (boundary 1 - fault, boundary 2 - constant pressure) (SI units), [kPa].
PO.PTA.Superposition.Time(t, prod_data, output)
The superposition time of a variable-rate drawdown, the abscissa that collapses every rate period onto one semilog straight line. Plot the pressure drop over the current rate, Δp/qn, against X (or against te on a log axis): in radial flow the points of every period fall on one line whose slope gives k and whose intercept gives the skin. With a single rate, te is the elapsed time itself. The rate history is laid out as `PO.PTA.Pw.VW`'s `prod_data`, so the same range drives the forward model and the interpretation.
PO.PTA.MDH.Fit(t, dp, q, B, mu, h, phi, ct, rw, output)
The Miller-Dyes-Hutchinson straight-line fit of a drawdown: the least-squares line through the pressure drop against log10 of time over the radial-flow points you pass, and the permeability and skin it gives. Pass only the points inside the infinite-acting radial-flow window, for example with `FILTER`. It also fits a multi-rate drawdown: pass the superposition time `PO.PTA.Superposition.Time(…, "te")` as t, the pressure drop scaled to a reference rate, Δp·qref/qn, as dp, and qref as q.
PO.PTA.Design.Rinv(k, t, phi, mu, ct)
How far the pressure transient of a rate change has reached into an infinite-acting radial reservoir after t hours. A test investigates the rock inside this radius; a boundary or a fault beyond it can't have been seen yet. Inverted, it gives the flow time needed to reach a target distance: t = (r / rinv at 1 h)².
PO.PTA.Design.Duration(C, mu, k, h, S, cycles)
How long a drawdown or buildup must run for its semilog straight line to be read. Wellbore storage and skin hide radial flow until (200000 + 12000·S)·C·μ/(k·h) hours; the test then needs the radial-flow line to span some log cycles of time beyond that to fit it with confidence. With `cycles` = 0 the function returns the start of the line itself; the PO test-design sheets use 1.5 cycles.
PO.PTA.Design.GaugeRes(m, resolution, L)
Whether a pressure gauge resolves the radial-flow derivative a test needs. In radial flow the Bourdet derivative is flat at m/ln(10), where m is the semilog slope; a gauge that can only tell pressures apart to its resolution δ puts an error of up to δ/L into a derivative taken over a smoothing window of L natural-log cycles. The function returns that error as a fraction of the flat derivative. The PO sheets call it good below 2 %, a fifth of the ±10 % band that identifies the radial-flow window, and unusable above 10 %, where the noise fills that band.