PO.PTA.Design.Rinv
Description
How far the pressure transient of a rate change has reached into an infinite-acting radial reservoir after t hours. A test investigates the rock inside this radius; a boundary or a fault beyond it can't have been seen yet. Inverted, it gives the flow time needed to reach a target distance: t = (r / rinv at 1 h)².
Formula
=LAMBDA(k, t, phi, mu, ct, SQRT(k*t/(948*phi*mu*ct)))Parameters
| Parameter | Unit | Description |
|---|---|---|
k |
mD | Permeability |
t |
h | Time since the rate change |
phi |
fraction | Porosity |
mu |
cp | Viscosity |
ct |
1/psi | Total compressibility |
Examples
| Invocation | Expected |
|---|---|
=PO.PTA.Design.Rinv(12.7, 7, 0.15, 1, 0.00000667) |
306.1527504 |
=PO.PTA.Design.Rinv(12.7*0.0359^2*948, 7, 0.15, 1, 0.00000667) |
338 |
=PO.PTA.Design.Rinv(50, 100, 0.2, 1, 0.000015) |
1325.928807 |