PO.PTA.Design.Rinv


Description

How far the pressure transient of a rate change has reached into an infinite-acting radial reservoir after t hours. A test investigates the rock inside this radius; a boundary or a fault beyond it can't have been seen yet. Inverted, it gives the flow time needed to reach a target distance: t = (r / rinv at 1 h)².

Formula

=LAMBDA(k, t, phi, mu, ct, SQRT(k*t/(948*phi*mu*ct)))

Parameters

Parameter Unit Description
k mD Permeability
t h Time since the rate change
phi fraction Porosity
mu cp Viscosity
ct 1/psi Total compressibility

Examples

Invocation Expected
=PO.PTA.Design.Rinv(12.7, 7, 0.15, 1, 0.00000667) 306.1527504
=PO.PTA.Design.Rinv(12.7*0.0359^2*948, 7, 0.15, 1, 0.00000667) 338
=PO.PTA.Design.Rinv(50, 100, 0.2, 1, 0.000015) 1325.928807