Liquid Pipelines LAMBDAs
Flow calculations and transport properties for liquid lines.
8 lambdas
PO.SF.PL.Liq.dP.SI(Ql, Rho_l, Ul, pipe_ID, pipe_length, pipe_roughness)
Pressure drop for liquid pipeline using Darcy-Weisbach equation (SI units), [kPa].
PO.SF.PL.Liq.Rate.SI(dP, Rho_l, Ul, pipe_ID, pipe_length, pipe_roughness)
Liquid flow rate for given pressure drop using Darcy-Weisbach (SI units), [m3/d].
PO.SF.PL.Liq.Pout.SI(P_in, Ql, Rho_l, Ul, pipe_ID, pipe_length, pipe_roughness, dH)
Outlet pressure for liquid pipeline (SI units), [kPa].
PO.SF.PL.Liq.Pin.SI(P_out, Ql, Rho_l, Ul, pipe_ID, pipe_length, pipe_roughness, dH)
Required inlet pressure for liquid pipeline (SI units), [kPa].
PO.SF.PL.Liq.Vel.SI(Ql, pipe_ID)
Liquid velocity in pipeline (SI units), [m/s].
PO.SF.PL.Liq.Re.SI(Ql, pipe_ID, Rho_l, Ul)
Reynolds number for liquid pipeline flow (SI units).
PO.SF.PL.Liq.Size(ql, rho, mu, length, eps, dh, p_in, p_min, v_max, ids)
Returns the smallest pipe internal diameter, from a list of candidate sizes, that carries a liquid rate from an inlet pressure to a minimum delivery pressure, the elevation change included, without exceeding a velocity limit. It sweeps the list smallest first with the shipped Darcy-Weisbach functions and stops at the first size that passes both tests. The roughness is the wall's absolute roughness, so each size takes its own relative roughness ε/D. A sheet reads the nominal size with `INDEX(nps, MATCH(size, ids, 0))`.
PO.SF.Pump.NPSHa(ps, pv, sg, hs, hf)
Returns the net positive suction head available at a pump's suction, in feet of the liquid pumped: how far the suction pressure stands above the liquid's vapour pressure. A pump needs at least the NPSH its curve requires at the duty, or the liquid flashes in the impeller eye and the pump cavitates. NPSHa = (ps − pv)·2.31/sg + hs − hf, where 2.31 ft of water is one psi.