PO.SF.PL.Liq.Rate.SI


Description

Liquid flow rate for given pressure drop using Darcy-Weisbach, [m3/d] (SI units).

Formula

=LAMBDA(dP, Rho_l, Ul, pipe_ID, pipe_length, pipe_roughness, LET( dP_psi, PO.UnitConverter(dP, "kPa", "psi"), Rho_l_lbft3, PO.UnitConverter(Rho_l, "kg/m3", "lb/ft3"), pipe_ID_in, PO.UnitConverter(pipe_ID, "cm", "in"), pipe_length_ft, PO.UnitConverter(pipe_length, "m", "ft"), result_bbld, PO.SF.PL.Liq.Rate(dP_psi, Rho_l_lbft3, Ul, pipe_ID_in, pipe_length_ft, pipe_roughness), PO.UnitConverter(result_bbld, "bbl/d", "m3/d")))

Parameters

Parameter Unit Description
dP kPa Available pressure drop, [kPa]
Rho_l kg/m3 Liquid density, [kg/m3]
Ul - Liquid viscosity, [cP]
pipe_ID cm Pipe inner diameter, [cm]
pipe_length m Pipe length, [m]
pipe_roughness - Relative roughness (e/D)

Examples

Invocation Expected
=PO.SF.PL.Liq.Rate.SI(3448, 800, 2, 6.35, 914.4, 0.0006) 156.7959

Need a custom LAMBDA? Suggest a New Lambda