PO.ESP.BrakeHP.SI

Calculates brake horsepower accounting for pump efficiency, [kW] (SI units).

1 function

PO.ESP.BrakeHP.FromRate.SI

Calculates brake horsepower directly from rate and head, [kW] (SI units).

1 function

PO.ESP.Cable.MinSize.SI

Determines minimum cable size for voltage drop limit, [AWG] (SI units).

1 function

PO.ESP.Cable.PowerLoss.SI

Calculates power loss in cable, [kW] (SI units).

1 function

PO.ESP.Cable.PowerLoss.Pct.SI

Calculates power loss as percentage of motor power, [%] (SI units).

1 function

PO.ESP.Cable.Resistance.SI

Returns cable resistance at temperature, [ohm/km] (SI units).

1 function

PO.ESP.Cable.Temperature.SI

Estimates cable temperature with current, [degC] (SI units).

1 function

PO.ESP.Cable.Vdrop.SI

Calculates voltage drop in ESP cable (3-phase), [V] (SI units).

1 function

PO.ESP.Cable.Vdrop.Full.SI

Complete voltage drop calculation, [V] (SI units).

1 function

PO.ESP.Curve.BEP.SI

Returns Best Efficiency Point flow rate from pump curve, [m3/d] (SI units).

1 function

PO.ESP.Curve.BEP.Eff.SI

Returns maximum efficiency value from pump curve, [fraction] (SI units).

1 function

PO.ESP.Curve.Efficiency.SI

Interpolates efficiency from pump performance curve, [fraction] (SI units).

1 function

PO.ESP.Curve.Head.SI

Interpolates head from pump performance curve, [m/stage] (SI units).

1 function

PO.ESP.Curve.Power.SI

Interpolates power per stage from pump curve, [kW] (SI units).

1 function

PO.ESP.Gas.Qg.Free.SI

Calculates free gas rate at pump intake conditions, [m3/d] (SI units).

1 function

PO.ESP.Gas.Ql.Total.SI

Calculates total liquid rate at pump intake, [m3/d] (SI units).

1 function

PO.ESP.Gas.RhoMix.SI

Calculates gas-liquid mixture density, [kg/m3] (SI units).

1 function

PO.ESP.Gas.Sep.Eff.SI

Estimates rotary gas separator efficiency, [fraction] (SI units).

1 function

PO.ESP.Gas.Turpin.Factor.SI

Calculates Turpin gas handling factor, [dimensionless] (SI units).

1 function

PO.ESP.Gas.Void.SI

Calculates gas void fraction at pump intake, [fraction] (SI units).

1 function

PO.ESP.Gas.Void.Full.SI

Complete gas void fraction calculation from field data, [fraction] (SI units).

1 function

PO.ESP.Head.FromPressure.SI

Converts pressure to head using fluid specific gravity, [m] (SI units).

1 function

PO.ESP.Head.PressureAtDepth.SI

Calculates pressure at depth given surface pressure, [kPa] (SI units).

1 function

PO.ESP.Head.Static.SI

Calculates static head from vertical depth, [m] (SI units).

1 function

PO.ESP.Head.ToPressure.SI

Converts head to pressure using fluid specific gravity, [kPa] (SI units).

1 function

PO.ESP.HydraulicHP.SI

Calculates theoretical hydraulic horsepower (bbl/d basis), [kW] (SI units).

1 function

PO.ESP.HydraulicHP.GPM.SI

Calculates theoretical hydraulic horsepower (gpm basis), [kW] (SI units).

1 function

PO.ESP.Motor.Amps.SI

Calculates motor current draw (3-phase), [A] (SI units).

1 function

PO.ESP.Motor.Amps.FromNameplate.SI

Calculates current from motor nameplate data, [A] (SI units).

1 function

PO.ESP.Motor.LoadFactor.SI

Calculates motor load as fraction of rating, [fraction] (SI units).

1 function

PO.ESP.Motor.Qcool.SI

Calculates minimum flow rate for motor cooling, [m3/d] (SI units).

1 function

PO.ESP.Motor.RequiredHP.SI

Calculates minimum motor horsepower with safety factor, [kW] (SI units).

1 function

PO.ESP.Motor.Temp.Rise.SI

Estimates motor temperature at operating conditions, [degC] (SI units).

1 function

PO.ESP.Nodal.AOF.SI

Calculates Absolute Open Flow potential, [m3/d] (SI units).

1 function

PO.ESP.Nodal.Drawdown.SI

Calculates drawdown at given production rate, [kPa] (SI units).

1 function

PO.ESP.Nodal.Submergence.SI

Calculates submergence above pump intake, [m] (SI units).

1 function

PO.ESP.Pump.Efficiency.SI

Calculates pump efficiency from hydraulic and brake HP, [fraction] (SI units).

1 function

PO.ESP.Pump.Pdis.SI

Calculates pump discharge pressure, [kPa] (SI units).

1 function

PO.ESP.Pump.TotalHead.SI

Calculates total head from number of stages, [m] (SI units).

1 function

PO.ESP.Pump.TotalPower.SI

Calculates total power from number of stages, [kW] (SI units).

1 function

PO.ESP.Stages.SI

Calculates required number of pump stages (rounded up), [stages] (SI units).

1 function

PO.ESP.Stages.Actual.SI

Returns exact (non-rounded) stage count for sensitivity analysis, [stages] (SI units).

1 function

PO.ESP.System.Hfric.SI

Simplified friction head calculation, [m] (SI units).

1 function

PO.ESP.TDH.SI

Calculates Total Dynamic Head for ESP sizing, [m] (SI units).

1 function

PO.ESP.TDH.Full.SI

Extended TDH calculation with IPR-based PIP, [m] (SI units).

1 function

PO.ESP.TDH.NetLift.SI

Calculates net vertical lift (pump depth minus fluid level), [m] (SI units).

1 function

PO.ESP.Viscosity.Head.Corr.SI

Applies viscosity correction to head, [m] (SI units).

1 function

PO.ESP.Viscosity.Rate.Corr.SI

Applies viscosity correction to flow rate, [m3/h] (SI units).

1 function

Need a custom LAMBDA? Request a Lambda