PO.ESP.Gas.Ql.Total.SI


Description

Calculates total liquid rate at pump intake, [m3/d] (SI units).

Formula

=LAMBDA(Qo, Qw, Bo, Bw, LET( Qo_STBd, PO.UnitConverter(Qo, "m3/d", "STB/d"), Qw_STBd, PO.UnitConverter(Qw, "m3/d", "STB/d"), result_bbld, PO.ESP.Gas.Ql.Total(Qo_STBd, Qw_STBd, Bo, Bw), PO.UnitConverter(result_bbld, "bbl/d", "m3/d")))

Parameters

Parameter Unit Description
Qo m3/d Oil rate, [m3/d]
Qw m3/d Water rate, [m3/d]
Bo - Oil FVF at intake, [m3/sm3]
Bw - Water FVF at intake, [m3/sm3]

Examples

Invocation Expected
=PO.ESP.Gas.Ql.Total.SI(159, 15.9, 1.2, 1.01) 206.859

Need a custom LAMBDA? Suggest a New Lambda