PO.ESP.Gas.Ql.Total.SI
Description
Calculates total liquid rate at pump intake, [m3/d] (SI units).
Formula
=LAMBDA(Qo, Qw, Bo, Bw, LET(
Qo_STBd, PO.UnitConverter(Qo, "m3/d", "STB/d"),
Qw_STBd, PO.UnitConverter(Qw, "m3/d", "STB/d"),
result_bbld, PO.ESP.Gas.Ql.Total(Qo_STBd, Qw_STBd, Bo, Bw),
PO.UnitConverter(result_bbld, "bbl/d", "m3/d")))Parameters
| Parameter | Unit | Description |
|---|---|---|
Qo |
m3/d | Oil rate, [m3/d] |
Qw |
m3/d | Water rate, [m3/d] |
Bo |
- | Oil FVF at intake, [m3/sm3] |
Bw |
- | Water FVF at intake, [m3/sm3] |
Examples
| Invocation | Expected |
|---|---|
=PO.ESP.Gas.Ql.Total.SI(159, 15.9, 1.2, 1.01) |
206.859 |