PO.ESP.Motor.Amps.SI


Description

Calculates motor current draw (3-phase), [A] (SI units).

Formula

=LAMBDA(HP, voltage, efficiency, power_factor, LET( HP_hp, PO.UnitConverter(HP, "kW", "hp"), PO.ESP.Motor.Amps(HP_hp, voltage, efficiency, power_factor)))

Parameters

Parameter Unit Description
HP kW Motor horsepower, [kW]
voltage - Operating voltage, [V]
efficiency - Motor efficiency, [fraction]
power_factor - Power factor, [fraction]

Examples

Invocation Expected
=PO.ESP.Motor.Amps.SI(5.6, 1, 0.6, 1) 5390.7713

Need a custom LAMBDA? Suggest a New Lambda