PO.ESP.Motor.Amps.SI
Description
Calculates motor current draw (3-phase), [A] (SI units).
Formula
=LAMBDA(HP, voltage, efficiency, power_factor, LET(
HP_hp, PO.UnitConverter(HP, "kW", "hp"),
PO.ESP.Motor.Amps(HP_hp, voltage, efficiency, power_factor)))Parameters
| Parameter | Unit | Description |
|---|---|---|
HP |
kW | Motor horsepower, [kW] |
voltage |
- | Operating voltage, [V] |
efficiency |
- | Motor efficiency, [fraction] |
power_factor |
- | Power factor, [fraction] |
Examples
| Invocation | Expected |
|---|---|
=PO.ESP.Motor.Amps.SI(5.6, 1, 0.6, 1) |
5390.7713 |