PO.ESP.Viscosity.Head.Corr.SI


Description

Applies viscosity correction to head, [m] (SI units).

Formula

=LAMBDA(H_water, C_H, LET( H_water_ft, PO.UnitConverter(H_water, "m", "ft"), result_ft, PO.ESP.Viscosity.Head.Corr(H_water_ft, C_H), PO.UnitConverter(result_ft, "ft", "m")))

Parameters

Parameter Unit Description
H_water m Head on water, [m]
C_H - Head correction factor, [dimensionless]

Examples

Invocation Expected
=PO.ESP.Viscosity.Head.Corr.SI(30.48, 1) 30.48

Need a custom LAMBDA? Suggest a New Lambda