PO.VFP.Liq.Pout.SI(Ql, P_in, Rho_l, Ul, pipe_ID, pipe_length, pipe_roughness, pipe_angle)

Calculates outlet pipe pressure for single phase pipe flow of incompressible, Newtonian fluid (SI units), [kPa].

PO.VFP.Liq.Pin.SI(Ql, P_out, Rho_l, Ul, pipe_ID, pipe_length, pipe_roughness, pipe_angle)

Calculates inlet pipe pressure for single phase pipe flow of incompressible, Newtonian fluid (SI units), [kPa].

PO.VFP.Liq.Re.SI(Ql, Rho_l, pipe_ID, Ul)

Calculates Reynolds number for single phase pipe flow of incompressible, Newtonian fluid (SI units), [dimensionless].

PO.VFP.Liq.dPfrc.SI(Ql, Rho_l, Ul, pipe_ID, pipe_length, pipe_roughness)

Calculates frictional pressure drop from Fanning equation for single-phase flow of an incompressible, Newtonian fluid (SI units), [kPa].

PO.VFP.Liq.dPgrv.SI(Rho_l, pipe_length, pipe_angle)

Calculates potential energy pressure drop for single-phase flow of an incompressible, Newtonian fluid (SI units), [kPa].

PO.PE.Inj.FracPressure(frac_gradient, tvd, fluid_gradient, friction, margin)

How hard can an injector be pushed at the wellhead before the bottomhole pressure fractures the formation? The bottomhole pressure of a water injector is the surface pressure plus the liquid column, less what the tubing loses to friction at the rate. The LAMBDA turns that round: the largest surface injection pressure is the fracture pressure at the sandface, less the column, plus the friction, less a safety margin kept below fracture pressure. It is the maximum allowable surface injection pressure (MASP) an injection permit or a pump selection starts from.

Need a custom LAMBDA? Request a Lambda