PO.PE.Inj.FracPressure
Description
How hard can an injector be pushed at the wellhead before the bottomhole pressure fractures the formation? The bottomhole pressure of a water injector is the surface pressure plus the liquid column, less what the tubing loses to friction at the rate. The LAMBDA turns that round: the largest surface injection pressure is the fracture pressure at the sandface, less the column, plus the friction, less a safety margin kept below fracture pressure. It is the maximum allowable surface injection pressure (MASP) an injection permit or a pump selection starts from.
Formula
=LAMBDA(frac_gradient, tvd, fluid_gradient, friction, margin, IF(OR(frac_gradient<=0, tvd<=0, fluid_gradient<=0, friction<0, margin<0), NA(), frac_gradient*tvd-fluid_gradient*tvd+friction-margin))Parameters
| Parameter | Unit | Description |
|---|---|---|
frac_gradient |
psi/ft | The formation's fracture gradient, from a step-rate or leak-off test; above 0 |
tvd |
ft | True vertical depth of the injection interval; above 0 |
fluid_gradient |
psi/ft | The injected liquid's hydrostatic gradient, its density in lb/ft³ over 144; above 0 |
friction |
psi | The tubing's friction loss at the injection rate (`PO.VFP.Liq.dPfrc`); 0 or more |
margin |
psi | The safety margin kept below fracture pressure; 0 or more |
Examples
| Invocation | Expected |
|---|---|
=PO.PE.Inj.FracPressure(0.72, 8500, 0.446533, 196.1658, 200) |
2320.6353 |
=PO.PE.Inj.FracPressure(0.8, 10000, 0.465, 300, 0) |
3650 |
=PO.PE.Inj.FracPressure(0.75, 5000, 0.46331, 0, 0) |
1433.45 |
=PO.PE.Inj.FracPressure(0.72, 8500, 0.446533, 0, 200) |
2124.4695 |