PO.PE.Plunger.Feasibility
Description
Can a conventional plunger lift this well? Foss and Gaul (1965) worked out the casing pressure a plunger needs to bring a liquid slug to surface: enough to push the plunger's weight, the slug's head and friction and the tubing pressure, plus the friction of the gas below the plunger, which grows with depth. The function returns that minimum casing pressure at the end of the rise, the maximum the casing must reach before the plunger leaves bottom (the gas then expands from the annulus into the tubing), and the rule-of-thumb gas the well must make, 400 scf per barrel of liquid for every 1,000 ft of lift. "Go" is 1 when the well's gas-liquid ratio and the casing pressure it builds up to meet both, 0 when either falls short.
Formula
=LAMBDA(depth, tubing_id, tubing_od, casing_id, plunger_wt, pt, slug, k, plhf, glr, pc, output, IF(OR(depth<=0, tubing_id<=0, tubing_od<tubing_id, casing_id<=tubing_od, plunger_wt<0, pt<0, slug<=0, k<=0, plhf<=0, glr<0, pc<0), NA(), LET(
at, PI()*tubing_id^2/4, aa, PI()*(casing_id^2-tubing_od^2)/4, pcmin, (plunger_wt/at+pt+plhf*slug)*(1+depth/k), pcmax, pcmin*(aa+at)/aa, glrmin, 0.4*depth, IF(output="PcMin", pcmin, IF(output="PcMax", pcmax, IF(output="GLRMin", glrmin, IF(output="Go", (glr>=glrmin)*(pc>=pcmax), NA())))))))Parameters
| Parameter | Unit | Description |
|---|---|---|
depth |
ft | Depth of the plunger's bottom stop; above 0 |
tubing_id |
in | Tubing inner diameter; above 0 |
tubing_od |
in | Tubing outer diameter; at least tubing_id |
casing_id |
in | Casing inner diameter; above tubing_od |
plunger_wt |
lb | Plunger weight; 0 or more |
pt |
psi | Tubing (line) pressure the plunger surfaces against; 0 or more |
slug |
bbl | Liquid slug lifted each cycle; above 0 |
k |
ft | Foss and Gaul's gas-friction constant for the tubing size: 33,500 for 2-3/8 in, 45,000 for 2-7/8 in; above 0 |
plhf |
psi/bbl | Foss and Gaul's slug head plus friction per barrel for the tubing size: 165 for 2-3/8 in, 102 for 2-7/8 in; above 0 |
glr |
scf/bbl | The well's producing gas-liquid ratio; 0 or more |
pc |
psi | The casing pressure the well builds up to in the shut-in (for a first look, its shut-in casing pressure); 0 or more |
output |
text | "PcMin" minimum casing pressure [psi], "PcMax" casing pressure needed at the start of the rise [psi], "GLRMin" required gas-liquid ratio [scf/bbl], or "Go" (1 feasible, 0 not) |
Examples
| Invocation | Expected |
|---|---|
=PO.PE.Plunger.Feasibility(8000, 1.995, 2.375, 4.892, 10, 100, 0.5, 33500, 165, 3500, 300, "PcMin") |
230.045122 |
=PO.PE.Plunger.Feasibility(8000, 1.995, 2.375, 4.892, 10, 100, 0.5, 33500, 165, 3500, 300, "PcMax") |
280.101619 |
=PO.PE.Plunger.Feasibility(8000, 1.995, 2.375, 4.892, 10, 100, 0.5, 33500, 165, 3500, 300, "GLRMin") |
3200 |
=PO.PE.Plunger.Feasibility(8000, 1.995, 2.375, 4.892, 10, 100, 0.5, 33500, 165, 3500, 300, "Go") |
1 |
=PO.PE.Plunger.Feasibility(8000, 1.995, 2.375, 4.892, 10, 100, 0.5, 33500, 165, 3000, 300, "Go") |
0 |
=PO.PE.Plunger.Feasibility(8000, 1.995, 2.375, 4.892, 10, 100, 0.5, 33500, 165, 3500, 250, "Go") |
0 |
=PO.PE.Plunger.Feasibility(6000, 2.441, 2.875, 6.276, 9, 150, 1, 45000, 102, 3000, 300, "PcMax") |
342.875626 |
=IF(ISNA(PO.PE.Plunger.Feasibility(8000, 1.995, 2.375, 4.892, 10, 100, 0.5, 33500, 165, 3500, 300, "Pc")), 1, 0) |
1 |