PO.PE.Loading.LiRate


Description

The least gas rate that keeps a gas well unloaded by Li, Li and Sun's (2001) flat-droplet model, in MMscf/d, at a pressure and temperature in a tubing size. Turner assumed the liquid drops the gas carries stay round; Li et al. argued that the pressure difference across a drop in a fast gas flattens it into an ellipsoid, which the gas lifts far more easily. Their critical velocity is about 38 % of Turner's adjusted one, so the well can flow at a much lower rate before it loads. The arguments are TurnerRate's, in the same order, without Turner's adjustment factor: put the two side by side to bracket where the well loads. The gas's Z-factor and density come from the pressure and temperature, by Dranchuk-Abou-Kassem at Sutton's pseudo-critical properties, as in TurnerRate.

Formula

=LAMBDA(p_psia, t_degF, sg_gas, tubingID_in, sigma_dyncm, rhoL_lbft3, IF(OR(p_psia<=0, t_degF<=-459.67, sg_gas<=0, tubingID_in<=0, sigma_dyncm<=0, rhoL_lbft3<=0), NA(), LET( tr, t_degF+459.67, z, PO.PVT.Z.ByDAK(p_psia/PO.PVT.Ppc.BySutton(sg_gas), tr/PO.PVT.Tpc.BySutton(sg_gas)), rho_g, PO.PVT.Rho.Gas.ByDefinition(p_psia, tr, sg_gas, z)*62.428, IF(rhoL_lbft3<=rho_g, NA(), 3.06*p_psia*0.72907*sigma_dyncm^0.25*(rhoL_lbft3-rho_g)^0.25/rho_g^0.5*PI()*tubingID_in^2/576/(tr*z)))))

Parameters

Parameter Unit Description
p_psia psia Flowing pressure the rate is read at, usually the wellhead's; above 0
t_degF °F Flowing temperature there
sg_gas — Gas specific gravity (air = 1), a sweet gas; above 0
tubingID_in in Tubing inner diameter; above 0
sigma_dyncm dyne/cm The liquid's surface tension against the gas: 60 for water, 20 for condensate; above 0
rhoL_lbft3 lb/ft³ The liquid's density: 67 for water, 45 for condensate; above the gas's

Examples

Invocation Expected
=PO.PE.Loading.LiRate(500, 100, 0.7, 2.441, 60, 67) 0.410125
=PO.PE.Loading.LiRate(500, 100, 0.7, 2.441, 20, 45) 0.281139
=PO.PE.Loading.LiRate(500, 100, 0.7, 3.958, 60, 67) 1.07828
=PO.PE.Loading.LiRate(3000, 160, 0.7, 2.441, 60, 67) 0.958436
=PO.PE.Loading.LiRate(100, 120, 0.6, 1.995, 60, 67) 0.126361
=IF(ISNA(PO.PE.Loading.LiRate(500, 100, 0.7, 2.441, 60, 0)), 1, 0) 1

Need a custom LAMBDA? Suggest a New Lambda