PO.SF.Sep.SoudersBrown(orientation, qg, p, t, z, sg, rho_l, k_sb, output)

Returns the allowable gas velocity in a separator by the Souders-Brown equation, or the smallest vessel internal diameter that keeps the gas below it. The allowable velocity is the speed at which liquid droplets of the size the mist extractor can catch still settle against the rising or crossing gas: Vt = K·√((ρl − ρg)/ρg). The vessel needs enough gas flow area that the actual gas flow, at the vessel's pressure and temperature, moves no faster. A vertical vessel passes the gas up through its whole cross-section. A horizontal one is taken half full of liquid, so the gas has the upper half. K is the caller's, from the vessel's internals: see the Validity note for the API 12J and GPSA ranges.

PO.SF.Sep.LiquidRetention(phases, orientation, qo, qw, tr_o, tr_w, d, output)

Returns the liquid volume a separator must hold so its liquid stays in the vessel for the design retention time, or the length of vessel of a given internal diameter that holds it. A two-phase separator holds the oil and water together for one time, long enough for the gas to come out of the liquid. A three-phase separator holds each for its own time, long enough for the water to drop out of the oil and the oil out of the water. A vertical vessel holds the liquid over its whole cross-section, so the length is the liquid height. A horizontal one is taken half full, Arnold and Stewart's design basis, so the length is the effective length the liquid occupies.