PO.SF.Sep.LiquidRetention
Description
Returns the liquid volume a separator must hold so its liquid stays in the vessel for the design retention time, or the length of vessel of a given internal diameter that holds it. A two-phase separator holds the oil and water together for one time, long enough for the gas to come out of the liquid. A three-phase separator holds each for its own time, long enough for the water to drop out of the oil and the oil out of the water. A vertical vessel holds the liquid over its whole cross-section, so the length is the liquid height. A horizontal one is taken half full, Arnold and Stewart's design basis, so the length is the effective length the liquid occupies.
Formula
=LAMBDA(phases, orientation, qo, qw, tr_o, tr_w, d, output, IF(OR(AND(phases<>2, phases<>3), AND(orientation<>"Vertical", orientation<>"Horizontal"), qo<0, qw<0, tr_o<0, tr_w<0, d<=0), NA(), IF(OR(output="Volume", output="Length"), IF(phases=2, (qo+qw)*tr_o, qo*tr_o+qw*tr_w)/1440*IF(output="Volume", 1, 5.6145833)/IF(output="Volume", 1, PI()/4*(d/12)^2*IF(orientation="Vertical", 1, 0.5)), NA())))Parameters
| Parameter | Unit | Description |
|---|---|---|
phases |
— | 2 (gas-liquid: the oil and water are held together for `tr_o`; `tr_w` is not used) or 3 (gas-oil-water: oil for `tr_o`, water for `tr_w`) |
orientation |
text | "Vertical" (liquid over the whole section) or "Horizontal" (half full) |
qo |
bbl/d | Oil (or condensate) rate; 0 or more |
qw |
bbl/d | Water rate; 0 or more |
tr_o |
min | Retention time of the oil, or of all the liquid in a two-phase vessel; 0 or more |
tr_w |
min | Retention time of the water in a three-phase vessel; 0 or more |
d |
in | Vessel internal diameter |
output |
text | "Volume" liquid volume held [bbl] or "Length" liquid height (vertical) or effective length (horizontal) [ft] |
Examples
| Invocation | Expected |
|---|---|
=PO.SF.Sep.LiquidRetention(2, "Horizontal", 2000, 0, 3, 0, 48, "Volume") |
4.166667 |
=PO.SF.Sep.LiquidRetention(2, "Horizontal", 2000, 0, 3, 0, 48, "Length") |
3.723286 |
=PO.SF.Sep.LiquidRetention(2, "Vertical", 2000, 0, 3, 0, 48, "Length") |
1.861643 |
=PO.SF.Sep.LiquidRetention(3, "Horizontal", 5000, 3000, 10, 10, 72, "Volume") |
55.555556 |
=PO.SF.Sep.LiquidRetention(3, "Horizontal", 5000, 3000, 10, 10, 72, "Length") |
22.063918 |
=PO.SF.Sep.LiquidRetention(3, "Vertical", 1500, 1000, 5, 8, 60, "Volume") |
10.763889 |
=PO.SF.Sep.LiquidRetention(3, "Vertical", 1500, 1000, 5, 8, 60, "Length") |
3.077917 |
=PO.SF.Sep.LiquidRetention(2, "Horizontal", 1500, 1000, 2, 8, 60, "Length") |
1.985753 |
=IF(ISNA(PO.SF.Sep.LiquidRetention(4, "Horizontal", 1500, 1000, 2, 8, 60, "Length")), 1, 0) |
1 |