PO.VFP.Liq.Re.SI


Description

Calculates Reynolds number for single phase pipe flow of incompressible, Newtonian fluid, [dimensionless] (SI units).

Formula

=LAMBDA(Ql, Rho_l, pipe_ID, Ul, LET( Ql_bbld, PO.UnitConverter(Ql, "m3/d", "bbl/d"), Rho_l_lbft3, PO.UnitConverter(Rho_l, "kg/m3", "lb/ft3"), pipe_ID_in, PO.UnitConverter(pipe_ID, "cm", "in"), PO.VFP.Liq.Re(Ql_bbld, Rho_l_lbft3, pipe_ID_in, Ul)))

Parameters

Parameter Unit Description
Ql m3/d Liquid rate, [m3/d]
Rho_l kg/m3 Liquid density, [kg/m3]
pipe_ID cm Pipe inner diameter, [cm]
Ul - Liquid viscosity, [cP]

Examples

Invocation Expected
=PO.VFP.Liq.Re.SI(159, 800, 6.35, 2) 14784.12

Need a custom LAMBDA? Suggest a New Lambda