PO.ESP.Motor.Temp.Rise.SI


Description

Estimates motor temperature at operating conditions, [degC] (SI units).

Formula

=LAMBDA(T_fluid, HP, Q, motor_OD, LET( T_fluid_degF, PO.UnitConverter(T_fluid, "degC", "degF"), HP_hp, PO.UnitConverter(HP, "kW", "hp"), Q_bbld, PO.UnitConverter(Q, "m3/d", "bbl/d"), motor_OD_in, PO.UnitConverter(motor_OD, "cm", "in"), result_degF, PO.ESP.Motor.Temp.Rise(T_fluid_degF, HP_hp, Q_bbld, motor_OD_in), PO.UnitConverter(result_degF, "degF", "degC")))

Parameters

Parameter Unit Description
T_fluid degC Fluid temperature past motor, [degC]
HP kW Motor HP, [kW]
Q m3/d Fluid flow rate past motor, [m3/d]
motor_OD cm Motor outside diameter, [cm]

Examples

Invocation Expected
=PO.ESP.Motor.Temp.Rise.SI(93.33, 5.6, 0.159, 6.35) 96.454802

Need a custom LAMBDA? Suggest a New Lambda