PO.RP.Pump.VolEff.SI


Description

Calculates volumetric efficiency of the pump system, [fraction] (SI units).

Formula

=LAMBDA(Qa, PD, LET( Qa_bbld, PO.UnitConverter(Qa, "m3/d", "bbl/d"), PD_bbld, PO.UnitConverter(PD, "m3/d", "bbl/d"), PO.RP.Pump.VolEff(Qa_bbld, PD_bbld)))

Parameters

Parameter Unit Description
Qa m3/d Actual production rate, [m3/d]
PD m3/d Theoretical pump displacement, [m3/d]

Examples

Invocation Expected
=PO.RP.Pump.VolEff.SI(159, 5) 1

Need a custom LAMBDA? Suggest a New Lambda