PO.ESP.Curve.HeadAtSpeed
Description
Head per stage at a rate and a frequency, from a pump curve published at the base frequency. The rate is moved back to the base frequency, q × f_base / f, the curve is read there with PO.ESP.Curve.Head, and the head is moved forward with the affinity law (f / f_base)². Past the curve's run-out the result is 0, which keeps a tabulated operating-point solve monotone.
Formula
=LAMBDA(q, f, f_base, curve_q, curve_head, IF(q*f_base/f>MAX(curve_q), 0, PO.ESP.Curve.Head(q*f_base/f, curve_q, curve_head)*(f/f_base)^2))Parameters
| Parameter | Unit | Description |
|---|---|---|
q |
bbl/d | Rate at the operating frequency |
f |
Hz | Operating frequency |
f_base |
Hz | Base frequency of the curve |
curve_q |
bbl/d | Curve rates at the base frequency |
curve_head |
ft/stage | Curve head per stage at the base frequency |
Examples
| Invocation | Expected |
|---|---|
=PO.ESP.Curve.HeadAtSpeed(500, 30, 60, {0, 500, 1000, 1500, 2000}, {100, 90, 70, 40, 10}) |
17.5 |
=PO.ESP.Curve.HeadAtSpeed(2500, 60, 60, {0, 500, 1000, 1500, 2000}, {100, 90, 70, 40, 10}) |
0 |