PO.ESP.Curve.HeadAtSpeed


Description

Head per stage at a rate and a frequency, from a pump curve published at the base frequency. The rate is moved back to the base frequency, q × f_base / f, the curve is read there with PO.ESP.Curve.Head, and the head is moved forward with the affinity law (f / f_base)². Past the curve's run-out the result is 0, which keeps a tabulated operating-point solve monotone.

Formula

=LAMBDA(q, f, f_base, curve_q, curve_head, IF(q*f_base/f>MAX(curve_q), 0, PO.ESP.Curve.Head(q*f_base/f, curve_q, curve_head)*(f/f_base)^2))

Parameters

Parameter Unit Description
q bbl/d Rate at the operating frequency
f Hz Operating frequency
f_base Hz Base frequency of the curve
curve_q bbl/d Curve rates at the base frequency
curve_head ft/stage Curve head per stage at the base frequency

Examples

Invocation Expected
=PO.ESP.Curve.HeadAtSpeed(500, 30, 60, {0, 500, 1000, 1500, 2000}, {100, 90, 70, 40, 10}) 17.5
=PO.ESP.Curve.HeadAtSpeed(2500, 60, 60, {0, 500, 1000, 1500, 2000}, {100, 90, 70, 40, 10}) 0

Need a custom LAMBDA? Suggest a New Lambda