PO.ESP.Affinity.Power


Description

Pump brake power at a new speed from the power at the base frequency, by the affinity laws. p(f) = p × (f / f_base)³. Any power unit works; the result is in the same unit.

Formula

=LAMBDA(p, f, f_base, p*(f/f_base)^3)

Parameters

Parameter Unit Description
p HP Power at the base frequency
f Hz Operating frequency
f_base Hz Base frequency of the catalog curve

Examples

Invocation Expected
=PO.ESP.Affinity.Power(0.9, 30, 60) 0.1125
=PO.ESP.Affinity.Power(0.9, 66, 60) 1.1979

Need a custom LAMBDA? Suggest a New Lambda