PO.DE.AnnularCapacity


Description

Volume per foot of the annulus between a hole (or casing ID) and the pipe inside it. Capacity = (Dh² − Dp²) / 1029.4 bbl/ft, with Dh the hole or casing inside diameter and Dp the pipe outside diameter.

Formula

=LAMBDA(Dh_in, Dp_in, (Dh_in^2 - Dp_in^2) / 1029.4)

Parameters

Parameter Unit Description
Dh_in in Hole diameter, or casing inside diameter
Dp_in in Pipe outside diameter

Examples

Invocation Expected
=PO.DE.AnnularCapacity(8.5, 5) 0.045900525
=PO.DE.AnnularCapacity(12.25, 6.5) 0.10473334

Need a custom LAMBDA? Suggest a New Lambda