PO.DE.Accumulator.PressureAfterDraw


Description

Pressure left in an accumulator bottle after some of its fluid is used. P = V P_pre / (V P_pre / P_max + V_drawn) psi: the nitrogen volume at P_max grows by the fluid drawn.

Formula

=LAMBDA(V_bottle_gal, P_precharge_psi, P_max_psi, V_drawn_gal, V_bottle_gal * P_precharge_psi / (V_bottle_gal * P_precharge_psi / P_max_psi + V_drawn_gal))

Parameters

Parameter Unit Description
V_bottle_gal gal Bottle volume
P_precharge_psi psi Nitrogen precharge pressure
P_max_psi psi Charged pressure
V_drawn_gal gal Fluid drawn from the bottle

Examples

Invocation Expected
=PO.DE.Accumulator.PressureAfterDraw(10, 1000, 3000, 2) 1875
=PO.DE.Accumulator.PressureAfterDraw(10, 1000, 3000, 5) 1200

Need a custom LAMBDA? Suggest a New Lambda