BOP Accumulator Sizing
Blueprint Preview
56 rows x 4 columns
| A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | BOP Accumulator Sizing | ||||||||||||||
| 2 | Blue cells on yellow are inputs. The function volumes are EXAMPLE values: take yours from the BOP manufacturer's data. | ||||||||||||||
| 3 | |||||||||||||||
| 4 | Accumulator Bottles | ||||||||||||||
| 5 | Bottle nitrogen volume (an 11 gal bottle holds 10) | 10 | gal | ||||||||||||
| 6 | Nitrogen precharge pressure | 1000 | psi | ||||||||||||
| 7 | Minimum operating pressure | 1200 | psi | ||||||||||||
| 8 | Accumulator operating pressure (fully charged) | 3000 | psi | ||||||||||||
| 9 | Bottles installed | 16 | bottles | ||||||||||||
| 10 | Design factor on the required volume | 1.5 | — | ||||||||||||
| 11 | |||||||||||||||
| 12 | BOP Functions | ||||||||||||||
| 13 | Function | Volume each (gal) | Count | Total (gal) | |||||||||||
| 14 | Annular preventer (close) | 17.1 | 1 | 17.1 | |||||||||||
| 15 | Pipe rams (close) | 5.8 | 2 | 11.6 | |||||||||||
| 16 | Blind/shear rams (close) | 6.2 | 1 | 6.2 | |||||||||||
| 17 | HCR valves (open) | 0.5 | 2 | 1.0 | |||||||||||
| 18 | Fluid to operate every function once | 35.9 | |||||||||||||
| 19 | |||||||||||||||
| 20 | Sizing | ||||||||||||||
| 21 | Usable fluid per bottle | 5.00 | gal | ||||||||||||
| 22 | Fluid required (functions × design factor) | 53.85 | gal | ||||||||||||
| 23 | Bottles required | 11 | bottles | ||||||||||||
| 24 | Usable fluid installed | 80.0 | gal | ||||||||||||
| 25 | Pressure after operating every function once, pumps off | 1,793 | psi | ||||||||||||
| 26 | Bottle count check | OK: enough bottles installed | |||||||||||||
| 27 | Remaining pressure check | OK: above the minimum operating pressure | |||||||||||||
| 28 | Precharge check | OK: minimum operating pressure 200 psi or more above precharge | |||||||||||||
| 29 | |||||||||||||||
| 30 | Accumulator Pressure as Fluid Is Drawn (all bottles, pumps off) | ||||||||||||||
| 31 | Fluid drawn (gal) | Pressure (psi) | Minimum operating (psi) | ||||||||||||
| 32 | 0.0 | 3,000 | 1,200 | ||||||||||||
| 33 | 5.3 | 2,727 | 1,200 | ||||||||||||
| 34 | 10.7 | 2,500 | 1,200 | ||||||||||||
| 35 | 16.0 | 2,308 | 1,200 | ||||||||||||
| 36 | 21.3 | 2,143 | 1,200 | ||||||||||||
| 37 | 26.7 | 2,000 | 1,200 | ||||||||||||
| 38 | 32.0 | 1,875 | 1,200 | ||||||||||||
| 39 | 37.3 | 1,765 | 1,200 | ||||||||||||
| 40 | 42.7 | 1,667 | 1,200 | ||||||||||||
| 41 | 48.0 | 1,579 | 1,200 | ||||||||||||
| 42 | 53.3 | 1,500 | 1,200 | ||||||||||||
| 43 | 58.7 | 1,429 | 1,200 | ||||||||||||
| 44 | 64.0 | 1,364 | 1,200 | ||||||||||||
| 45 | 69.3 | 1,304 | 1,200 | ||||||||||||
| 46 | 74.7 | 1,250 | 1,200 | ||||||||||||
| 47 | 80.0 | 1,200 | 1,200 | ||||||||||||
| 48 | 85.3 | 1,154 | 1,200 | ||||||||||||
| 49 | 90.7 | 1,111 | 1,200 | ||||||||||||
| 50 | 96.0 | 1,071 | 1,200 | ||||||||||||
| 51 | 101.3 | 1,034 | 1,200 | ||||||||||||
| 52 | 106.7 | 1,000 | 1,200 | ||||||||||||
| 53 | |||||||||||||||
| 54 | Fluid required (gal) | Pressure (psi) | |||||||||||||
| 55 | 53.85 | 0 | |||||||||||||
| 56 | 53.85 | 3000 |
| Name | Refers To | Comment |
|---|---|---|
| _PO.DE.Accumulator.UsableVolume | =LAMBDA(V_bottle_gal, P_precharge_psi, P_min_psi, P_max_psi, V_bottle_gal * P_precharge_psi * (1 / P_min_psi - 1 / P_max_psi)) | Usable hydraulic fluid per accumulator bottle, gal, between the minimum and maximum operating pressures (Boyle's law on the nitrogen precharge). |
| _PO.DE.Accumulator.PressureAfterDraw | =LAMBDA(V_bottle_gal, P_precharge_psi, P_max_psi, V_drawn_gal, V_bottle_gal * P_precharge_psi / (V_bottle_gal * P_precharge_psi / P_max_psi + V_drawn_gal)) | Accumulator pressure, psi, after V_drawn gal is drawn from a bottle charged to P_max (Boyle's law on the nitrogen precharge). |
| ACC_Vb | $B$5 | Bottle nitrogen volume (an 11 gal bottle holds 10), gal |
| ACC_Pre | $B$6 | Nitrogen precharge pressure, psi |
| ACC_Pmin | $B$7 | Minimum operating pressure, psi |
| ACC_Pmax | $B$8 | Accumulator operating pressure (fully charged), psi |
| ACC_N | $B$9 | Bottles installed, bottles |
| ACC_SF | $B$10 | Design factor on the required volume |
| ACC_Vfn | $D$18 | Fluid to operate every BOP function once, gal |
Description
Sizes a BOP accumulator unit. Enter the bottle size, the precharge, the minimum and fully charged operating pressures, the bottles installed and a design factor, and list the fluid each BOP function takes. The sheet returns the usable fluid per bottle, the fluid required, the number of bottles that needs and the pressure left after operating every function once with the pumps off. Checks cover the bottle count, the remaining pressure and the precharge margin. A chart shows accumulator pressure against the fluid drawn, with the minimum operating pressure and the required volume marked.
Parameters:
- Bottle volume: Nitrogen volume per bottle (gal). An 11 gal bottle holds 10 gal.
- Precharge, minimum and operating pressure: Nitrogen precharge, the lowest pressure the system may fall to, and the fully charged pressure (psi)
- Bottles installed, design factor: Count and the factor applied to the functions' volume (dimensionless)
- BOP functions: Fluid to operate each function (gal) and how many there are. The shipped values are examples; use the BOP manufacturer's data.
Method: The precharge nitrogen follows Boyle's law, so a bottle charged to P_max gives up V × P_pre × (1/P_min − 1/P_max) of fluid by the time it falls to P_min. Fluid required = the functions' total × the design factor. Bottles required = required / usable per bottle, rounded up. After V_d of fluid is drawn from each bottle, the pressure is V × P_pre / (V × P_pre / P_max + V_d), which gives the drawdown curve and the pressure left after one sequence. A design factor of 1.5 on the close volume is a common rule of thumb; API Standard 53 and API 16D set the requirement for a specific rig, and this sheet does not replace them. The formulas are the sheet's own _PO.DE.* LAMBDAs, so it calculates with no add-in installed.
Example: 10 gal bottles precharged to 1,000 psi and worked between 3,000 and 1,200 psi give 5.0 gal each. The example stack takes 35.9 gal, or 53.85 gal with a 1.5 design factor, so 11 bottles. The 16 installed hold 80 gal usable and are left at about 1,790 psi after operating every function once.
How to use this blueprint
- In Excel, go to the Petroleum Office ribbon tab and click Blueprint Manager
- Search for BOP Accumulator Sizing
- Click on the blueprint to preview
- Click Insert to place it into your worksheet. Modify the input values to match your data.