PO.DE.Casing.LoadCase
Description
Net pressure load on a casing string at one depth for the standard burst and collapse load cases, with the external backup. Evaluated down a depth column, it gives the load line that the burst or collapse rating is compared against. Cases 1 and 2 (burst) return internal minus external pressure in psi, cases 3 and 4 (collapse) external minus internal.
Formula
=LAMBDA(Case, D_ft, Pref_psi, Dref_ft, Gin_psift, Gout_psift, Level_ft, LET(
pout, Gout_psift*D_ft,
pburst, Pref_psi-Gin_psift*(Dref_ft-D_ft),
pevac, IF(Case=3, 0, IF(D_ft>Level_ft, Gin_psift*(D_ft-Level_ft), 0)),
IF(OR(Case<1, Case>4), NA(), IF(Case<=2, pburst-pout, pout-pevac))))Parameters
| Parameter | Unit | Description |
|---|---|---|
Case |
dimensionless | 1 burst gas to surface; 2 burst lost returns with water; 3 collapse full evacuation; 4 collapse partial evacuation |
D_ft |
ft | True vertical depth of the point |
Pref_psi |
psi | Burst: pressure at the reference depth (pore pressure for case 1, fracture pressure for case 2) |
Dref_ft |
ft | Burst: true vertical depth of the reference pressure |
Gin_psift |
psi/ft | Internal fluid gradient: gas (case 1), water (case 2) or the fluid below the level (case 4) |
Gout_psift |
psi/ft | External gradient: the backup for burst, the mud outside for collapse |
Level_ft |
ft | Case 4: depth of the fluid level inside the casing |
Examples
| Invocation | Expected |
|---|---|
=PO.DE.Casing.LoadCase(1, 0, 5000, 10000, 0.1, 0.465, 0) |
4000 |
=PO.DE.Casing.LoadCase(1, 10000, 5000, 10000, 0.1, 0.465, 0) |
350 |
=PO.DE.Casing.LoadCase(2, 0, 6400, 8000, 0.465, 0, 0) |
2680 |
=PO.DE.Casing.LoadCase(2, 8000, 6400, 8000, 0.465, 0.465, 0) |
2680 |
=PO.DE.Casing.LoadCase(3, 10000, 0, 0, 0, 0.52, 0) |
5200 |
=PO.DE.Casing.LoadCase(4, 10000, 0, 0, 0.52, 0.52, 4000) |
2080 |
=PO.DE.Casing.LoadCase(4, 3000, 0, 0, 0.52, 0.52, 4000) |
1560 |