Casing Design LAMBDAs
Pipe-body ratings per API TR 5C3, the load line they are checked against, and the design factor and triaxial stress that decide whether a string holds.
6 lambdas
PO.DE.Casing.Burst.API5C3
Pipe-body internal yield pressure (the burst rating) of casing or tubing, as API TR 5C3 and ISO 10400 tabulate it for API 5CT pipe. P = 0.875 × 2 Yp t / D psi: Barlow's equation at the API 5CT minimum wall of 87.5% of nominal.
PO.DE.Casing.Collapse.API5C3
Minimum collapse resistance of casing or tubing under external pressure, by the four API collapse equations. The regime is chosen from the D/t ratio and the grade, and axial tension can reduce the rating through the API axial-stress equivalent grade. Output 0 returns the collapse pressure in psi, 1 adds the regime (1 yield, 2 plastic, 3 transition, 4 elastic) as a second cell, and 2 returns the grade's three regime D/t limits.
PO.DE.Casing.Axial.Yield
Pipe-body yield strength of casing or tubing: the axial tension at which the body reaches the minimum yield strength of its grade. Fy = (π/4)(D² − d²) Yp lbf, with d = D − 2t.
PO.DE.Casing.LoadCase
Net pressure load on a casing string at one depth for the standard burst and collapse load cases, with the external backup. Evaluated down a depth column, it gives the load line that the burst or collapse rating is compared against. Cases 1 and 2 (burst) return internal minus external pressure in psi, cases 3 and 4 (collapse) external minus internal.
PO.DE.Casing.DesignFactor
Design factor of a casing string against one load, and whether it meets the minimum design factor set for that load. DF = Rating / Load. Returns two cells: DF, then 1 when DF ≥ DF_min and 0 otherwise.
PO.DE.Casing.VonMises
Triaxial equivalent stress in a casing or tubing wall at radius r, for a triaxial design check against the minimum yield strength. The triaxial design factor is Yp divided by this stress. σvm = √{[(σa − σr)² + (σr − σθ)² + (σθ − σa)²] / 2} psi, with σr and σθ from Lamé's thick-wall equations.