PO.DE.Casing.VonMises


Description

Triaxial equivalent stress in a casing or tubing wall at radius r, for a triaxial design check against the minimum yield strength. The triaxial design factor is Yp divided by this stress. σvm = √{[(σa − σr)² + (σr − σθ)² + (σθ − σa)²] / 2} psi, with σr and σθ from Lamé's thick-wall equations.

Formula

=LAMBDA(WallOD_in, t_in, Pi_psi, Po_psi, Sa_psi, r_in, LET( ro, WallOD_in/2, ri, ro-t_in, k, ro^2-ri^2, mean, (Pi_psi*ri^2-Po_psi*ro^2)/k, dev, (Pi_psi-Po_psi)*ri^2*ro^2/(k*r_in^2), sr, mean-dev, sh, mean+dev, SQRT(((Sa_psi-sr)^2+(sr-sh)^2+(sh-Sa_psi)^2)/2)))

Parameters

Parameter Unit Description
WallOD_in in Specified outside diameter
t_in in Wall thickness
Pi_psi psi Internal pressure
Po_psi psi External pressure
Sa_psi psi Axial stress, tension positive
r_in in Radius at which to evaluate, ri ≤ r ≤ ro; usually ri = OD/2 − t

Examples

Invocation Expected
=PO.DE.Casing.VonMises(10, 0.5, 0, 7600, 0, 4.5) 80000
=PO.DE.Casing.VonMises(10, 0.5, 5000, 0, 0, 5) 42631.57895
=PO.DE.Casing.VonMises(10, 0.5, 5000, 0, 0, 4.5) 50318.23931
=PO.DE.Casing.VonMises(9.625, 0.472, 5000, 2000, 30000, 4.3405) 33672.24826
=PO.DE.Casing.VonMises(9.625, 0.472, 5000, 2000, -20000, 4.3405) 41738.28068

Need a custom LAMBDA? Suggest a New Lambda