PO.GM.Density.Gardner


Description

Bulk density from P-wave velocity by Gardner's power law, the usual stand-in for a density log over a section logged only with sonic. Fill a density column with it, then pass the column to `PO.GM.Stress.Overburden`. Returns the bulk density in g/cc.

Formula

=LAMBDA(Vp, A, B, A*Vp^B)

Parameters

Parameter Unit Description
Vp ft/s or m/s P-wave velocity; 1,000,000 / Δt for a sonic transit time in µs/ft
A — Gardner coefficient: 0.23 for Vp in ft/s, 0.31 for Vp in m/s, or a local calibration
B — Gardner exponent: 0.25, or a local calibration

Examples

Invocation Expected
=PO.GM.Density.Gardner(10000, 0.23, 0.25) 2.3
=PO.GM.Density.Gardner(3048, 0.31, 0.25) 2.303379167
=PO.GM.Density.Gardner(8000, 0.23, 0.25) 2.175205701

Need a custom LAMBDA? Suggest a New Lambda