PO.RES.Waterflood.VRR
Description
The voidage replacement ratio of a waterflood or a pattern: the reservoir volume injected over the reservoir volume withdrawn, per period or cumulative. A VRR of 1 holds the reservoir pressure; above 1 the pressure rises, below 1 it falls. Withdrawal counts the oil, the free gas (produced gas less the gas that was in solution in the produced oil) and the water, each at reservoir conditions. Injection counts the water and any gas injected.
Formula
=LAMBDA(Np, Wp, Gp, Bo, Bw, Bg, Rs, Wi, Gi, Mode, LET(
inj, Wi*Bw+Gi*Bg,
wd, Np*Bo+(Gp-Np*Rs)*Bg+Wp*Bw,
IF(Mode=1, inj/wd, IF(Mode=2, SCAN(0, inj, LAMBDA(acc, v, acc+v))/SCAN(0, wd, LAMBDA(acc, v, acc+v)), NA()))))Parameters
| Parameter | Unit | Description |
|---|---|---|
Np |
STB | Oil produced in each period, one column |
Wp |
STB | Water produced in each period, same rows |
Gp |
scf | Gas produced in each period, same rows |
Bo |
rb/STB | Oil formation volume factor: one value, or one per period |
Bw |
rb/STB | Water formation volume factor, for both produced and injected water |
Bg |
rb/scf | Gas formation volume factor, for both free produced gas and injected gas |
Rs |
scf/STB | Solution gas-oil ratio |
Wi |
STB | Water injected in each period, same rows |
Gi |
scf | Gas injected in each period, same rows (zeros for a waterflood) |
Mode |
— | 1 VRR of each period; 2 cumulative VRR to the end of each period |
Examples
| Invocation | Expected |
|---|---|
=PO.RES.Waterflood.VRR({10000;12000}, {2000;5000}, {8000000;9000000}, 1.25, 1.02, 0.0009, 500, {20000;25000}, {0;1000000}, 1) |
[1.183294664, 1.157894737] |
=PO.RES.Waterflood.VRR({10000;12000}, {2000;5000}, {8000000;9000000}, 1.25, 1.02, 0.0009, 500, {20000;25000}, {0;1000000}, 2) |
[1.183294664, 1.168831169] |
=PO.RES.Waterflood.VRR({10000}, {0}, {5000000}, 1.2, 1, 0.001, 500, {12000}, {0}, 1) |
1 |