PO.RES.Waterflood.VRR


Description

The voidage replacement ratio of a waterflood or a pattern: the reservoir volume injected over the reservoir volume withdrawn, per period or cumulative. A VRR of 1 holds the reservoir pressure; above 1 the pressure rises, below 1 it falls. Withdrawal counts the oil, the free gas (produced gas less the gas that was in solution in the produced oil) and the water, each at reservoir conditions. Injection counts the water and any gas injected.

Formula

=LAMBDA(Np, Wp, Gp, Bo, Bw, Bg, Rs, Wi, Gi, Mode, LET( inj, Wi*Bw+Gi*Bg, wd, Np*Bo+(Gp-Np*Rs)*Bg+Wp*Bw, IF(Mode=1, inj/wd, IF(Mode=2, SCAN(0, inj, LAMBDA(acc, v, acc+v))/SCAN(0, wd, LAMBDA(acc, v, acc+v)), NA()))))

Parameters

Parameter Unit Description
Np STB Oil produced in each period, one column
Wp STB Water produced in each period, same rows
Gp scf Gas produced in each period, same rows
Bo rb/STB Oil formation volume factor: one value, or one per period
Bw rb/STB Water formation volume factor, for both produced and injected water
Bg rb/scf Gas formation volume factor, for both free produced gas and injected gas
Rs scf/STB Solution gas-oil ratio
Wi STB Water injected in each period, same rows
Gi scf Gas injected in each period, same rows (zeros for a waterflood)
Mode — 1 VRR of each period; 2 cumulative VRR to the end of each period

Examples

Invocation Expected
=PO.RES.Waterflood.VRR({10000;12000}, {2000;5000}, {8000000;9000000}, 1.25, 1.02, 0.0009, 500, {20000;25000}, {0;1000000}, 1) [1.183294664, 1.157894737]
=PO.RES.Waterflood.VRR({10000;12000}, {2000;5000}, {8000000;9000000}, 1.25, 1.02, 0.0009, 500, {20000;25000}, {0;1000000}, 2) [1.183294664, 1.168831169]
=PO.RES.Waterflood.VRR({10000}, {0}, {5000000}, 1.2, 1, 0.001, 500, {12000}, {0}, 1) 1

Need a custom LAMBDA? Suggest a New Lambda