PO.SCAL.PcToHeight
Description
The height above the free water level (FWL) at which a reservoir holds a given capillary pressure, starting from a laboratory measurement. The laboratory Pc is first carried to the reservoir fluid system by the ratio of σ·cosθ, the interfacial tension times the cosine of the contact angle, and then balanced against the buoyancy of the oil column: h = 144·Pc_res/(ρw − ρo). Pass the same σ and θ twice when the Pc is already at reservoir conditions. The saturation-height sheets read Sw against height with it.
Formula
=LAMBDA(Pc, ift_lab, theta_lab, ift_res, theta_res, rho_w, rho_o, LET(
lab_term, ift_lab*COS(RADIANS(theta_lab)),
res_term, ift_res*COS(RADIANS(theta_res)),
drho, rho_w-rho_o,
IF(OR(drho<=0, lab_term<=0, res_term<0), NA(), 144*Pc*res_term/lab_term/drho)))Parameters
| Parameter | Unit | Description |
|---|---|---|
Pc |
psi | Capillary pressure measured in the laboratory fluid system |
ift_lab |
dyne/cm | Interfacial (or surface) tension of the laboratory fluid pair |
theta_lab |
degrees | Contact angle of the laboratory fluid pair |
ift_res |
dyne/cm | Interfacial tension of the reservoir oil-water pair |
theta_res |
degrees | Contact angle of the reservoir oil-water pair |
rho_w |
lb/ft³ | Water density at reservoir conditions |
rho_o |
lb/ft³ | Oil density at reservoir conditions |
Examples
| Invocation | Expected |
|---|---|
=PO.SCAL.PcToHeight(0.75, 50, 0, 50, 0, 65.2, 55.2) |
10.8 |
=PO.SCAL.PcToHeight(2.35, 50, 0, 50, 0, 65.2, 55.2) |
33.84 |
=PO.SCAL.PcToHeight(1.05, 50, 0, 50, 0, 65.2, 55.2) |
15.12 |
=PO.SCAL.PcToHeight(10, 72, 0, 30, 30, 65.2, 55.2) |
51.96152423 |
=IF(ISNA(PO.SCAL.PcToHeight(1, 50, 0, 50, 0, 55, 60)), 1, 0) |
1 |