PO.SCAL.BrooksCorey.Pc.SI


Description

Brooks-Corey capillary pressure, [kPa]. Pc = Pd × Se^(-1/λ) (SI units).

Formula

=LAMBDA(Sw, Swi, Pd, lambda, LET( Pd_psi, PO.UnitConverter(Pd, "kPa", "psi"), result_psi, PO.SCAL.BrooksCorey.Pc(Sw, Swi, Pd_psi, lambda), PO.UnitConverter(result_psi, "psi", "kPa")))

Parameters

Parameter Unit Description
Sw - Water saturation, [fraction]
Swi - Irreducible water saturation, [fraction]
Pd kPa Displacement (entry) pressure, [kPa]
lambda - Pore size distribution index, [dimensionless]. Typical 0.5-6

Examples

Invocation Expected
=PO.SCAL.BrooksCorey.Pc.SI(0.5, 0.2, 2068.5, 2) 3377.8464

Need a custom LAMBDA? Suggest a New Lambda