PO.FRAC.Design.PadFraction


Description

The share of the slurry volume to pump as pad, clean fluid ahead of the proppant, from the fluid efficiency of the treatment: ε = (1 − η)/(1 + η) (Nolte, 1986). The same number is the exponent of Nolte's proppant ramp, c(t) = ce·[(t − tpad)/(te − tpad)]^ε, which leaves the whole created length propped at a uniform concentration at the end of pumping. A low efficiency, from high leakoff, needs a large pad.

Formula

=LAMBDA(eta, IF(OR(eta<=0, eta>1), NA(), (1-eta)/(1+eta)))

Parameters

Parameter Unit Description
eta fraction Fluid (slurry) efficiency at the end of pumping: the fracture volume over the volume injected

Examples

Invocation Expected
=PO.FRAC.Design.PadFraction(0.193) 0.677
=PO.FRAC.Design.PadFraction(0.5) 0.333333333
=PO.FRAC.Design.PadFraction(1) 0
=IF(ISNA(PO.FRAC.Design.PadFraction(0)), 1, 0) 1

Need a custom LAMBDA? Suggest a New Lambda