The fracturing-fluid efficiency of an injection, from the G-function value at which the fracture closed on its falloff. Efficiency is the share of the injected volume still in the fracture at shut-in; the rest has leaked off. Nolte's material balance ties it to the time the fracture takes to close: a fracture that closes quickly (small Gc) lost most of its fluid while it was pumped. The leakoff exponent α is a required mode, the same one used for the G-function (`PO.FRAC.DFIT.GFunction`). With α = 0.5 the result is Barree's η = Gc/(2 + Gc).
Nolte's G-function of a fracture falloff, the time axis of the G-function plot that a diagnostic fracture injection test (DFIT) is read on. You pass the shut-in times, the pumping time and the falloff pressures. The function returns, as a column, the dimensionless shut-in time ΔtD, Nolte's g(ΔtD), G(ΔtD), the pressure derivative dP/dG, or the superposition derivative G·dP/dG. While the fracture is open and leakoff is normal, the pressure falls on a straight line against G and G·dP/dG on a straight line through the origin. Closure is where G·dP/dG leaves that line. Pressure-dependent leakoff, height recession and tip extension each bend it in their own way. The leakoff exponent α is a required mode: 1 for a fracture whose area grows linearly with time (low leakoff, high efficiency, the usual choice) and 0.5 for one whose area grows with √t (high leakoff, low efficiency).