PO.FRAC.KGD.Length.Leakoff.SI


Description

Khristianovic-Geertsma-de Klerk (KGD) fracture half-length with Carter leakoff, [m] (SI units).

Formula

=LAMBDA(Q, Ul, h, G, C, t, LET( Q_bblmin, PO.UnitConverter(Q, "m3/min", "bbl/min"), h_ft, PO.UnitConverter(h, "m", "ft"), G_psi, PO.UnitConverter(G, "kPa", "psi"), C_ft, PO.UnitConverter(C, "m", "ft"), result_ft, PO.FRAC.KGD.Length.Leakoff(Q_bblmin, Ul, h_ft, G_psi, C_ft, t), PO.UnitConverter(result_ft, "ft", "m")))

Parameters

Parameter Unit Description
Q m3/min Injection rate (both wings), [m3/min]
Ul - Fluid viscosity, [cP]
h m Fracture height, [m]
G kPa Shear modulus, [kPa]
C m/sqrt(min) Carter leakoff coefficient, [m/sqrt(min)]
t - Pumping time, [min]

Examples

Invocation Expected
=PO.FRAC.KGD.Length.Leakoff.SI(0.159, 2, 3.048, 8273708, 0.003048, 100) 27.2388

Need a custom LAMBDA? Suggest a New Lambda