PO.FRAC.KGD.Width.General.SI
Description
Khristianovic-Geertsma-de Klerk (KGD) fracture width (generalized with Poisson's ratio), [cm] (SI units).
Formula
=LAMBDA(Q, Ul, L, h, E, nu, LET(
Q_bblmin, PO.UnitConverter(Q, "m3/min", "bbl/min"),
L_ft, PO.UnitConverter(L, "m", "ft"),
h_ft, PO.UnitConverter(h, "m", "ft"),
E_psi, PO.UnitConverter(E, "kPa", "psi"),
result_in, PO.FRAC.KGD.Width.General(Q_bblmin, Ul, L_ft, h_ft, E_psi, nu),
PO.UnitConverter(result_in, "in", "cm")))Parameters
| Parameter | Unit | Description |
|---|---|---|
Q |
m3/min | Injection rate (both wings), [m3/min] |
Ul |
- | Fluid viscosity, [cP] |
L |
m | Fracture half-length, [m] |
h |
m | Fracture height, [m] |
E |
kPa | Young's modulus, [kPa] |
nu |
- | Poisson's ratio, [dimensionless] |
Examples
| Invocation | Expected |
|---|---|
=PO.FRAC.KGD.Width.General.SI(0.159, 2, 304.8, 30.48, 20680000, 0.25) |
2.17502 |