PO.FRAC.KGD.Width.SI


Description

Khristianovic-Geertsma-de Klerk (KGD) fracture width at wellbore, [cm] (SI units).

Formula

=LAMBDA(Q, Ul, L, h, G, LET( Q_bblmin, PO.UnitConverter(Q, "m3/min", "bbl/min"), L_ft, PO.UnitConverter(L, "m", "ft"), h_ft, PO.UnitConverter(h, "m", "ft"), G_psi, PO.UnitConverter(G, "kPa", "psi"), result_in, PO.FRAC.KGD.Width(Q_bblmin, Ul, L_ft, h_ft, G_psi), PO.UnitConverter(result_in, "in", "cm")))

Parameters

Parameter Unit Description
Q m3/min Injection rate (both wings), [m3/min]
Ul - Fluid viscosity, [cP]
L m Fracture half-length, [m]
h m Fracture height, [m]
G kPa Shear modulus, [kPa]

Examples

Invocation Expected
=PO.FRAC.KGD.Width.SI(0.159, 2, 304.8, 30.48, 22.62) 47.133076

Need a custom LAMBDA? Suggest a New Lambda