PO.FRAC.Proppant.Conductivity


Description

The conductivity a proppant pack keeps at the effective closure stress it carries in the well, and after the losses a laboratory cell doesn't see. A vendor's conductivity table (API RP 19D / ISO 13503-5) gives kf·w at a few closure stresses; between two of them conductivity falls close to exponentially with stress, so the function interpolates log-linearly, and extrapolates the same way past them. The result is multiplied by the share retained, a factor for gel residue, embedment, fines migration and cyclic loading, which typically leaves 20 to 60 % of the laboratory value. The conductivity lost is one minus the result over the laboratory value.

Formula

=LAMBDA(kfw_lo, sigma_lo, kfw_hi, sigma_hi, sigma_eff, retained, IF(OR(kfw_lo<=0, kfw_hi<=0, sigma_hi=sigma_lo, retained<0, retained>1), NA(), retained*kfw_lo*EXP(LN(kfw_hi/kfw_lo)*(sigma_eff-sigma_lo)/(sigma_hi-sigma_lo))))

Parameters

Parameter Unit Description
kfw_lo md·ft Laboratory conductivity at the lower test stress
sigma_lo psi The lower test stress
kfw_hi md·ft Laboratory conductivity at the higher test stress
sigma_hi psi The higher test stress
sigma_eff psi Effective closure stress on the pack: closure stress less the flowing bottomhole pressure
retained fraction Share of the laboratory conductivity retained in the well (1 for none lost)

Examples

Invocation Expected
=PO.FRAC.Proppant.Conductivity(5000, 2000, 2000, 6000, 4000, 1) 3162.27766
=PO.FRAC.Proppant.Conductivity(5000, 2000, 2000, 6000, 4000, 0.5) 1581.13883
=PO.FRAC.Proppant.Conductivity(5000, 2000, 2000, 6000, 2000, 1) 5000
=PO.FRAC.Proppant.Conductivity(5000, 2000, 2000, 6000, 8000, 1) 1264.91106
=IF(ISNA(PO.FRAC.Proppant.Conductivity(5000, 2000, 2000, 2000, 4000, 1)), 1, 0) 1

Need a custom LAMBDA? Suggest a New Lambda