PO.PP.Rw.FromRwa


Description

Formation-water resistivity as the smallest apparent water resistivity over a clean, water-bearing interval. Rwa = Rt φ^m / a is Archie solved for Rw at Sw = 1; in a water zone it equals Rw, and hydrocarbons only raise it, so the minimum is the best estimate. Returns Rw in ohm·m.

Formula

=LAMBDA(Rt_ohmm, Phi_frac, a_tort, m_cem, MIN(Rt_ohmm*Phi_frac^m_cem/a_tort))

Parameters

Parameter Unit Description
Rt_ohmm ohm·m True resistivity column over the interval
Phi_frac fraction Porosity column, same rows
a_tort dimensionless Tortuosity factor
m_cem dimensionless Cementation exponent

Examples

Invocation Expected
=PO.PP.Rw.FromRwa({2;1.5;1.25;3}, {0.2;0.25;0.22;0.18}, 1, 2) 0.0605
=PO.PP.Rw.FromRwa({2;1.5;1.25;3}, {0.2;0.25;0.22;0.18}, 0.81, 2) 0.074691358
=PO.PP.Rw.FromRwa(1.25, 0.2, 1, 2) 0.05

Need a custom LAMBDA? Suggest a New Lambda