PO.PP.Rw.FromRwa
Description
Formation-water resistivity as the smallest apparent water resistivity over a clean, water-bearing interval. Rwa = Rt φ^m / a is Archie solved for Rw at Sw = 1; in a water zone it equals Rw, and hydrocarbons only raise it, so the minimum is the best estimate. Returns Rw in ohm·m.
Formula
=LAMBDA(Rt_ohmm, Phi_frac, a_tort, m_cem, MIN(Rt_ohmm*Phi_frac^m_cem/a_tort))Parameters
| Parameter | Unit | Description |
|---|---|---|
Rt_ohmm |
ohm·m | True resistivity column over the interval |
Phi_frac |
fraction | Porosity column, same rows |
a_tort |
dimensionless | Tortuosity factor |
m_cem |
dimensionless | Cementation exponent |
Examples
| Invocation | Expected |
|---|---|
=PO.PP.Rw.FromRwa({2;1.5;1.25;3}, {0.2;0.25;0.22;0.18}, 1, 2) |
0.0605 |
=PO.PP.Rw.FromRwa({2;1.5;1.25;3}, {0.2;0.25;0.22;0.18}, 0.81, 2) |
0.074691358 |
=PO.PP.Rw.FromRwa(1.25, 0.2, 1, 2) |
0.05 |