PO.FRAC.Design.Conductivity


Description

The conductivity kf·wp of a propped fracture, from the mass of proppant placed, not from the hydraulic width the fracture had while it was pumped. After closure the fracture is as wide as its proppant pack: the pack's bulk volume, mass/((1 − φp)·ρp), spread over the two wings' area 2·xf·hf. The hydraulic width at the end of pumping is several times larger, so a dimensionless conductivity CfD = kf·w/(k·xf) worked from it overstates the fracture. Divide the result by kf for the propped width in ft, or pass it to `PO.FRAC.Well.Cfd` as kf with a width of 1.

Formula

=LAMBDA(mass, rho_p, phi_p, xf, hf, kf, IF(OR(mass<0, rho_p<=0, phi_p<0, phi_p>=1, xf<=0, hf<=0, kf<0), NA(), kf*mass/((1-phi_p)*rho_p)/(2*xf*hf)))

Parameters

Parameter Unit Description
mass lbm Proppant mass placed, both wings
rho_p lb/ft³ Proppant grain (particle) density
phi_p fraction Porosity of the proppant pack
xf ft Propped half-length
hf ft Propped fracture height
kf mD Proppant pack permeability (effective, at closure stress)

Examples

Invocation Expected
=PO.FRAC.Design.Conductivity(79200, 165, 0.4, 223.6068, 50, 50000) 1788.854
=PO.FRAC.Design.Conductivity(80000, 165, 0.35, 300, 100, 1) 0.012432
=IF(ISNA(PO.FRAC.Design.Conductivity(80000, 165, 1, 300, 100, 50000)), 1, 0) 1

Need a custom LAMBDA? Suggest a New Lambda