PO.RTA.NormalizedRate


Description

Returns the pressure-normalized oil rate of rate-transient analysis, q/(pi − pwf): the oil rate over the drawdown from the initial reservoir pressure to the flowing bottomhole pressure. It is the y axis of the Blasingame and Agarwal-Gardner plots, and it puts a well whose flowing pressure changes (a choke change, a pump speed-up) back on one decline, which a rate alone can't. Its reciprocal, (pi − pwf)/q, is the inverse normalized pressure a flowing material balance fits against material-balance time (`PO.RTA.FlowingMB`). It works on one value or on whole columns of rates and flowing pressures.

Formula

=LAMBDA(q, p_i, p_wf, IF((q<=0)+(p_i<=p_wf), NA(), q/(p_i-p_wf)))

Parameters

Parameter Unit Description
q STB/d Oil rate; above 0
p_i psi Initial reservoir pressure
p_wf psi Flowing bottomhole pressure, below p_i

Examples

Invocation Expected
=PO.RTA.NormalizedRate(577.4, 5000, 1000) 0.14435
=PO.RTA.NormalizedRate(114.8, 5000, 1000) 0.0287
=PO.RTA.NormalizedRate(500, 5000, 3700) 0.384615
=PO.RTA.NormalizedRate(1200, 3500, 2900) 2

Need a custom LAMBDA? Suggest a New Lambda