PO.PP.Rw.Temperature


Description

Converts a water, mud or mud-filtrate resistivity measured at one temperature to another, usually from surface or 75 °F to formation temperature, with Arps's relation. Returns the resistivity at T_F in the unit of R_ref.

Formula

=LAMBDA(R_ref, T_ref_F, T_F, R_ref*(T_ref_F+6.77)/(T_F+6.77))

Parameters

Parameter Unit Description
R_ref ohm·m Resistivity at the reference temperature
T_ref_F degF Temperature at which R_ref was measured
T_F degF Temperature to convert to

Examples

Invocation Expected
=PO.PP.Rw.Temperature(0.06, 75, 200) 0.023727814
=PO.PP.Rw.Temperature(0.1, 70, 180) 0.041104032
=PO.PP.Rw.Temperature(0.05, 150, 150) 0.05

Need a custom LAMBDA? Suggest a New Lambda