PO.SF.CH.Liq.Rate
Description
Liquid flow rate through choke, [bbl/d]. Uses Bernoulli equation for incompressible flow.
Syntax
=PO.SF.CH.Liq.Rate(d_choke, dP, Rho_l, Cd)Parameters
| Parameter | Description |
|---|---|
| d_choke | Choke diameter, [inches]. |
| dP | Pressure drop across choke, [psi]. |
| Rho_l | Liquid density, [lb/ft3]. |
| Cd | Discharge coefficient. |