PO.ESP.BrakeHP

Calculates brake horsepower accounting for pump efficiency, [HP].

PO.ESP.Cable.MinSize

Determines minimum cable size for voltage drop limit, [AWG].

PO.ESP.Cable.PowerLoss

Calculates power loss in cable, [kW].

PO.ESP.Cable.Resistance

Returns cable resistance at temperature, [ohm/1000ft].

PO.ESP.Cable.Vdrop

Calculates voltage drop in ESP cable (3-phase), [V].

PO.ESP.Cable.Vsurface

Calculates required surface voltage, [V].

PO.ESP.Curve.BEP

Returns Best Efficiency Point flow rate from pump curve, [bbl/d].

PO.ESP.Curve.Efficiency

Interpolates efficiency from pump performance curve, [fraction].

PO.ESP.Curve.Head

Interpolates head from pump performance curve, [ft/stage].

PO.ESP.Curve.Range.Status

Returns descriptive operating range status.

PO.ESP.Gas.DunbarFactor

Calculates Dunbar gas correction factor, [dimensionless].

PO.ESP.Gas.Recommendation

Returns gas handling recommendation based on void fraction.

PO.ESP.Gas.Sep.Eff

Estimates rotary gas separator efficiency, [fraction].

PO.ESP.Gas.TurpinFactor

Calculates Turpin gas handling factor, [dimensionless].

PO.ESP.Gas.Void

Calculates gas void fraction at pump intake, [fraction].

PO.ESP.Head.FromPressure

Converts pressure to head using fluid specific gravity, [ft].

PO.ESP.Head.Static

Calculates static head from vertical depth, [ft].

PO.ESP.Head.ToPressure

Converts head to pressure using fluid specific gravity, [psi].

PO.ESP.HydraulicHP

Calculates theoretical hydraulic horsepower (bbl/d basis), [HP].

PO.ESP.Motor.Amps

Calculates motor current draw (3-phase), [A].

PO.ESP.Motor.Eff.AtLoad

Estimates motor efficiency at partial load, [fraction].

PO.ESP.Motor.LoadFactor

Calculates motor load as fraction of rating, [fraction].

PO.ESP.Motor.RequiredHP

Calculates minimum motor horsepower with safety factor, [HP].

PO.ESP.Motor.Temp.Rise

Estimates motor temperature at operating conditions, [degF].

PO.ESP.Nodal.AOF

Calculates Absolute Open Flow potential, [STB/d].

PO.ESP.Nodal.Drawdown

Calculates drawdown at given production rate, [psi].

PO.ESP.Nodal.Submergence

Calculates submergence above pump intake, [ft].

PO.ESP.Pump.Efficiency

Calculates pump efficiency from hydraulic and brake HP, [fraction].

PO.ESP.Pump.Pdis

Calculates pump discharge pressure, [psi].

PO.ESP.Stages

Calculates required number of pump stages (rounded up), [stages].

PO.ESP.System.Hfric

Simplified friction head calculation, [ft].

PO.ESP.TDH

Calculates Total Dynamic Head for ESP sizing, [ft].

PO.ESP.TDH.Full

Extended TDH calculation with IPR-based PIP, [ft].

PO.ESP.Viscosity.Eff.Corr

Applies viscosity correction to efficiency, [fraction].

PO.ESP.Viscosity.Head.Corr

Applies viscosity correction to head, [ft].

PO.ESP.Viscosity.QuickFactor

Simplified viscosity correction for screening, [dimensionless].

Can't find what you need? Request a Formula